Page
9
of
14
a. Remove the detachable recovery tank from the vacuum cleaner
b. Place the poly liner at the bottom of the detachable recovery tank and pull the top
of the poly liner over the lip of the recovery tank. Please note that a poly liner
retainer plate with clip is available to hold down the poly liner.
c. Place back the detachable recovery tank on the vacuum cleaner
d. Disengage the latches and remove the powerhead from the middle ring.
e. If using an optional pre-filter place it in the middle ring by overlapping the filter’s
elastic over the lip of the middle ring. Make certain the elastic covers the entire
circumference of the middle ring.
f. Install the static dissipating main filter in the middle ring. Make certain that the
filter's gasket covers the entire circumference of the middle ring.
g. Place the powerhead on the middle ring and fasten the latches.
h. Connect a static dissipating air supply hose to the air inlet on the manifold (see
Fig. 1) placed on the side of the vacuum cleaner
i. Connect one or two suction / air supply hose(s) to the suction intake(s) (see Fig.
1) on the vacuum cleaner. If using only one suction hose with the vacuum
cleaner, close the unused suction intake with the storage plug to prevent loss of
suction.
j. Connect the static dissipating suction / air supply hoses to the compressed air
outlet on the manifold (see Fig. 1).
k. Connect the vacuum assisted sander or grinder to the static dissipating suction /
air supply hose. Follow the instructions provided with the vacuum assisted
sander or grinder to ensure proper operation.
l.
Connect the vacuum to a grounded electrical outlet.
m. To turn on the vacuum cleaner, turn switch to the ON position.
Содержание DETACHABLE TANK SERIES
Страница 42: ...Page 16 of 28 c Detach the recovery tank...