BlueWave® QX4® User Guide
10
Set Intensity, Determine Exposure Time
Users can specify light intensity and, through empirical testing, determine the exposure
time required to achieve a full cure. As with any manufacturing process, it is advisable to
incorporate a safety factor.
Control
Process validation confirms a minimum acceptable intensity. Users can then choose to
operate at full intensity (using the excess intensity as an additional safety factor) or
adjust the output to a specific intensity level. To ensure consistent and repeatable
process results, intensity levels should be monitored with a radiometer. This enables
users to identify light intensity changes and take corrective action (either adjusting the
light intensity or performing maintenance).
Front Control Panel
■
Front Control Panel Display
—
Displays the currently selected menu.
■
Up Button (
)
—
Navigates the selector up one position. It is also used to
increase the selection value.
■
Down Button (
)
—
Navigates the selector down one position. It is also used to
decrease the selection value.
■
Right Button (
)
—
Selects the highlighted option and advances the screen to
the next menu.
■
Left Button (
)
—
Navigates to the previous menu. Holding this button down
for more than one second will return you back to the main menu. It can also be
used to cancel a selected option and return to the previous menu.
■
Run Button (
)
—
Activates the irradiation when the run option is selected. This
button is also used as an enter button.
■
LED Head Indicators
—
Colored lights indicate the status of each connected
head. A green light indicates that a head is active. An orange light indicates an over-
temperature warning. A red light indicates that the critical temperature has been
exceeded.