USE R GUI DE
|
BL UE WAVE
®
A X -5 5 0
17
Figure 23.
Front Panel
Figure 24.
Initializing Screen
Figure 25.
Set and Modify a new value.
Operation
To operate the BlueWave AX-550 system:
1.
Verify that the Controller and Emitter are assembled
properly, the input power is correctly plugged into the AC
Inlet on the top of the unit, and the Interlock Jumpers (or
external safety sensor) are installed between Pins 4 & 5,
and 15 & 16 of the I/O Connector on the top of the unit.
2.
When all connections are properly made, toggle the Power
Switch on the top of the unit. The system is now ready for
use.
System Initialization
Upon startup of the unit, a splash screen displays the controller
and emitter FW versions. After about 6 seconds, the control
screen should appear in the display. The unit loads in
administrator mode the first time
it’s
started.
The control screen is used to set up and run curing cycles. Admin
screen allows users to switch back and forth between
admin/production mode if the PLC mode is disabled. Curing
parameters are set in the admin screen.
Rotary Pushbutton
The front panel on the controller features a rotary pushbutton which
can be used for function selection and for modifying all adjustable
irradiation parameters when not in PLC mode. Specific irradiation
settings may also be saved and loaded using the Program Load/Save
feature explained in a later section. All settings and status can be
viewed on a color LCD display.
•
Turning the rotary pushbutton moves the selection field as
indicated on the LCD display.
•
Pressing the center of the rotary pushbutton selects the menu
item or sets the input for the active field.
NOTE:
The selected value will appear in blue color, when selected
value requires modification press the rotary pushbutton, then, this
value will turn yellow indicating it is ready to be modified. Turning the
rotary pushbutton changes the value to be selected.
LCD
Display
Rotary
Push
Button
Control