8. Error Messages / Troubleshooting
4
5
18
7
16
Overload: The motor drive
detects excessive drive output
current. The motor drive can
endure 150% of rated current
for 60 seconds.
1. Check if the motor is overloaded.
2. Decrease the setting value at Pr01-23 to increase the output capacity of
the motor drive.
Electronics thermal relay
protection:
Motor is overloaded.
1. Check if the motor is overloaded.
2. Check if the setting of Pr00-13 <Motor Rated Current> is appropriate.
3. Check the setting of Pr04-13~ Pr04-14 <Electronic thermal relay> is
appropriate.
4. Increase the capacity of the motor.
Motor is overloaded:
The A/C motor drive detects
excessive drive output current.
1. Check if the motor is overloaded.
2. Check if the setting of Pr04-15~ Pr04-17 <Torque detection level> is
appropriate.
Internal EEPROM cannot be
programmed.
Check the voltage of input power then restart the motor drive.
Internal EEPROM cannot be
programmed.
Check if the power board and control board inside the motor are properly
installed. Press RESET key and set up the parameters to factory setting.
Содержание CT 900 LED
Страница 4: ...4 2 Elektronische Bauteile Obere Kontrollelemente Computer Lüfter Sicherheits clip ...
Страница 11: ...11 5 Gerätekonfiguration ...
Страница 12: ...12 6 Grundlegende Verbindungen Platinenoberseite Platinenunterseite ...
Страница 14: ...14 6 Grundlegende Verbindungen Layout der Steuerplatine VFD015TM12A ...
Страница 20: ...20 8 Fehlermeldungen Fehlerbehebung INCLINE E33 Fehler Flussdiagramm ...
Страница 26: ...26 8 Fehlermeldungen Fehlerbehebung Schaltplan ...
Страница 48: ...48 11 Installation des Steigungsmotors 11 1 Seriennummer ...
Страница 65: ...65 Console Hand Pulse A C Motor Inverter Board Incline Motor Lower Control Board 1 Device Outlines ...
Страница 66: ...66 2 Electronic Parts Upper Controls Console Cooling Fan Safety key ...
Страница 67: ...67 2 Electronic Parts Lower Controls and Drive A C Motor Incline Motor Inverter ...
Страница 73: ...73 5 Device Configuration ...
Страница 74: ...74 6 Basic Connections and Wiring PCB Board Top PCB Board Bottom ...
Страница 76: ...76 6 Basic Connections and Wiring Driver PCB Board Layout VFD015TM12A ...
Страница 82: ...82 8 Error Messages Troubleshooting INCLINE E33 Error action flow chart ...
Страница 88: ...88 8 Error Messages Troubleshooting Circuit diagram ...
Страница 91: ...91 8 Error Messages Troubleshooting ...
Страница 92: ...92 8 Error Messages Troubleshooting ...
Страница 93: ...93 8 Error Messages Troubleshooting ...
Страница 94: ...94 8 Error Messages Troubleshooting ...
Страница 95: ...95 8 Error Messages Troubleshooting ...
Страница 109: ...109 11 Installation of the Incline Motor Incline Range must be adjusted to 315 mm minimum prior to installation ...
Страница 110: ...110 11 Installation of the Incline Motor 11 1 Serial Number Location ...