![DX Engineering DXE-AL24 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/dx-engineering/dxe-al24/dxe-al24_manual_2545487010.webp)
- 9 -
Turn the case over and place the optional Hi-Z Plus-6 High Impedance Amplifier on the mounting
plate as shown in
Figure 6
.
Note the position of the two threaded studs and the label on the optional Hi-Z Plus-6 High
Impedance Amplifier when properly placed on the Mounting Plate.
While holding the optional Hi-Z Plus-6 High Impedance Amplifier case and lid firmly in place,
install the four new metric screws (Stainless Steel Machine Screw, Metric M4 x 40 mm, Phillips
Pan Head ) through the Mounting Plate into the Hi-Z Plus-6 High Impedance Amplifier. Tighten
snugly, but do not over tighten which may damage the plastic case.
Figure 6 - Attaching the optional Hi-Z Plus-6 High Impedance Amplifier
to the Mounting Plate
Using the 10-24 x 3/4” Hex Head Bolt and #10 hardware, install the grounding bolt and hardware in
the hole near the bottom of the Mounting Plate as shown in
Figure 7
. Install it snugly so it won’t
come loose while handling. A later step in this procedure will have you installing your ground
connection at this point.
Figure 7 - Ground Connection Hardware