6
R.O. Membrane:
The third and main stage of the filtration is R.O. membrane. It is “semi-permeable”, which
means that it allows water to pass through but prevents dissolved particles from passing
through. It splits the feed water into two streams: clean water goes to the post-filter and then
onto the tank and faucet. Waste water with rejected particles goes down the drain.
Post-Filter:
Last stage of filtration is an activated carbon post-filter and/or remineralization for fine con-
ditioning and keeping the extra freshness of your water.
Specification
Operating Requirements:
■
■
Minimum supply water pressure: 7.25 psi (0.05 MPa)
■
■
Maximum supply water pressure: 80 psi (0.55 MPa)
■
■
Minimum water temperature: 41
o
F (5
o
C)
■
■
Optimal water temperature: 59–77
o
F (15–25
o
C)
■
■
Maximum water temperature: 95
o
F (35
o
C) / up to 105
o
F (40.5
o
C) short-term
■
■
Ambient air temperature: 41–105
o
F (5–40.5
o
C)
■
■
Water source: tap water supply, chlorinated or non-chlorinated, bacteriologically safe
■
■
Supply water pH range: 4.0-11.0
■
■
Supply water turbidity: < 1 NTU
■
■
Supply water components: Hardness (CaCO
3
) <180 mg/L (<10.5 gpg), Iron <0.1 mg/L,
Manganese <0.05 mg/L, Hydrogen Sulfide 0.00 mg/L
■
■
Maximum supply water TDS: 1000 ppm
■
■
Indoor use only.
■
■
Electrical input: AC 100-240V 50/60 Hz
■
■
Maximum length of the line between the pump unit and the membrane (“split installa-
tion”): 50 ft (15 m) (purchase of extra tubing may be required)
■
■
Tubing: ¼”
Performance:
Performance of the appliance such as filtered water delivery rate, rejection rate, etc. is highly
dependent on local conditions (inlet water pressure, temperature, TDS and degree of contam-
ination, tank air pressure, etc.) and R.O. system use pattern. Actual performance may vary.
■
■
Filtered water production rating: 75 gpd (270 lpd) maximum
■
■
Filtered water delivery rate (from the tank), typical: 0.27–0.74 gpm (1–2.8 l/min)
■
■
Membrane rejection rate
1
, typical: 90%
■
■
Recovery rate (system efficiency
2
), typical: 15%
■
■
Drain water flow restrictor: 300 cc (ml/min) nominal, up to 360 cc in working mode, open
flow in flush mode.
■
■
Auto-flush duration: 18±10% s
■
■
Tank Storage Capacity (Total Volume): up to 2.5G (4.0G)
1
For all dissolved solids combined as measured by TDS or conductivity meter.
2
Efficiency rating means the percentage of the influent water to the system that is available to the user as
reverse osmosis treated water under operating conditions that approximate typical daily usage.