10
The maximum length of hose connections between the pump box unit and R.O. filtration unit
is 50 ft. You may place both units under your kitchen sink, or you may place the R.O. filtration
unit with the water storage tank under the sink in your kitchen near the faucet, and the pump
box unit in your bathroom near the electrical outlet, cold water supply and drain pipes.
Installation Steps:
1. Install adapter ball valve (included) to the
cold water supply.
Use some Teflon or plumbers sealing tape to
prevent leaks. Use three included threaded
adapters to make different connection con-
figurations (see chart for details).
2. Create ½” hole for the filtered water faucet and install it.
3 min
3 min
5-10
times
repeat
No skewed cut!
1
4
3
2
1
4
2
3
3/8”
3/8”
3/8”
1/2”
1/2”
1/2”
mount drain
saddle here
never
mount
here
never mount
here
Tip: If you have a soap dispenser or a water
sprayer in an existing hole you may remove it
and use its hole for the filtered water
faucet.
3. Install drain saddle.
3 min
3 min
5-10
times
repeat
No skewed cut!
1
4
3
2
1
4
2
3
3/8”
3/8”
3/8”
1/2”
1/2”
1/2”
mount drain
saddle here
never
mount
here
never mount
here
The square foam gasket with a circle cut out must be applied to the inside of the drain sad-
dle. Remove sticky tape backing and stick to the drain saddle as shown.
1
2
3
4
5
6
7
8
9
10
11
1. Faucet
2. Chrome washer
3. Black rubber washer
4. Countertop or
sink deck
5. Black washer
6. Lock washer
7. Lock nut
8. Insert
9. Sleeve
10. Compression nut
11. Tubing
UNEF 9/16”-24
G3/8”
G1/2”
G1/2”
Adapter
Adapter
UNEF 9/16”-24
UNEF 9/16”-24
G3/8”
G1/2”
1
Adapter
1
Adapter
2
3