![DWT BWT PERMAQ Pico 10-90 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/dwt/bwt-permaq-pico-10-90/bwt-permaq-pico-10-90_installation-and-operating-manual_2544518051.webp)
OPM BWT PERMAQ® Pico Rev. 2.0 EN
Technical data | 10
EN
51
10.3 Technical data for the BWT PERMAQ® Pico 40-90 HR on/
off
40
50
60
70
80
90
Permeate:
Offline output, free run-off
1)
l/h
> 380
> 830
> 1035
> 1380
> 1600
> 1960
Offline output, free run-off
2)
l/h
> 410
> 920
> 1250
> 1550
> 1840
> 2240
Online output, 3.0
bar counter pres-
sure
1)
l/h
> 355
> 770
> 965
> 1265
> 1510
> 1860
Online output, 3.0
bar counter pres-
sure
2)
l/h
> 380
> 840
> 1055
> 1350
> 1760
> 2160
Salt retention rate
%
99
Permeate yield (WCF)
%
80
Feed water
Pressure range
bar
2.5 – 6.0
Temperature range
°C
5 – 30
Hardness/with antiscalant dosing
°dH
°fH
0.0 / 25
0.0 / 45
Iron (Fe) and manganese (Mn)
mg/l
< 0.1
Salt content, total dissolved solids
(TDS)
mg/l
< 1,000
Silt density index (SDI)
%/min
< 3
Oxidants
mg/l
< 0.05
Silicate (SiO
2
)
mg/l
< 20
Hydraulic connections:
Feed water
Inch
3/4"
1"
Permeate
Inch
3/4"
1"
Concentrate
mm
13
mm / FT version 8
mm
13
mm / FT version 10
mm
General
Degree of protection
IP
63
Ambient temperature
°C
5 – 35
Electrical connection / fuse protec-
tion
V/Hz/
A
400/50/10
Electric power consumption
kW
1.6
2.3
2.3
3.1
3.1
3.1
Type of valve
VDC
24
Connector standard
CEE
16; 3PNE
1)
Feed water: TDS ≤ 1,000
mg/l; 15
°C; 2.5
bar
2)
Feed water: TDS ≤ 1,000
mg/l; 15
°C; 4.0
bar
Table
15:
Technical data for the BWT PERMAQ® Pico 40-90 HR on/off