- 28 -
HD-700 projector’s RS232 Control
The RS232 interface for HD-700 can be operated from any terminal, such as a Windows 95, 98
PC running HyperTerminal.
COMMUNICATION PORT SET-UP
CONNECTOR PIN-OUT
Baud Rate : 9600
2 TX (Transmit Data)
Parity : none
3 RX (Receive Data)
Stop bits : 1
5 GND (Signal Ground)
Num. of bits : 8 bits
Flow control : none
Each command is enclosed in the < > character envelope.
The following table lists the commands available.
POWER CONTROL
<PON> power on
<POFF>
power off
<p>
power toggle
DUPLICATING REMOTE CONTROL BUTTONS
<L>
left arrow
<R>
right arrow
<U>
up arrow
<D>
down arrow
<0>
0
<1>
1
<2>
2
<3>
3
<4>
4
<5>
5
<6>
6
<7>
7
<8>
8
<9>
9
<+10>
+10
<m>
menu
<e>
exit
<n>
enter
<i>
guide