background image

!

Accessories are optional and sold separately.

10

Camera Parts and ID Setup

Installation Using Ceiling / Wall Mount Bracket*

2

6

 8

INSTALLATION

Terminal Block Connections

1

2

3

5

6

7

INSTALLATION 

(OUTDOOR)

INSTALLATION

First Time Bootup and Initial Testing

Dome Cover

- Protects the camera module from outside environment.

- Do not detach protection film from the dome cover

   before finishing all installation to protect

   dome cover from scratches or dust.

Lockup Screw

Fixes main body to the surface mount bracket.

Fan

Fan for temperature control.

BNC Video Cable

Main video output cable.

9P Terminal Block Slot

9P terminal block that is connected with cables is

inserted in this slot.

LED & Reset Button

LED for active(yellow light), power(red light) status

and Reset button for reset camera.

ID Setup Switch

Specify the camera ID.

The ID number of the camera is set using binary 

numbers.

- If you want to control a certain camera, you must  

match the camera ID with ‘CAM ID’ setting of DVR or 

keyboard controller.

- The range of Camera ID is 0~255.

- All cameras have a factory default Camera ID of 1.

- Camera ID will be effective without having to reboot 

the camera.

¾” Pipe Mounting Hole

- This is used to pass the cables to the cameras. 

- When water protection is needed, connect the ¾” pipe

   through this hole, then pass the cables through the

   pipe.

Mounting Hole (x4)

This is used to attach the surface mount bracket to the

ceiling.

Surface Mount Bracket

The camera’s main body protects the camera’s wires. 

This part is required when installing the camera with 

an Indoor Accessory. 

2

1

5

3

4

6

7

8

9

Main Body

1

2

Bottom of Main Body

3

4
5

7

8

9

6

10

  

   

Drilling the Hole
on the Ceiling

Pass cables through
3/4” holes & mount 
Bracket.

2

2

1

3

5

2

1

5

3

4

Rubber Gasket

Template Sheet

Disassemble the main body with the 

surface mount before installation the 

camera.
Drilling 4 Holes on the Ceiling

Using provided template sheet, drill a hole 

(30mm diameter) on the ceiling panel to 

pass cables.

Fixing the Surface Mount Bracket

Pass the cables through the ¾” pipe hole, 

and screw the surface mount bracket to the 

ceiling.

Rubber Gasket

- Before installing the gasket, the hole in the 

center is  to be cut by knife when only necessary.

Connecting the Cables and the Terminal Block

Connect the cables to the terminal block and 

then put the terminal block in the slot of the 

main body.

Fixing the Main Body

Screw the main body to the surface mount 

bracket by screwing 4 lock-up screws.

Detaching the Protection Film

Detach the protection film from the dome 

cover after finishing all installation.

4

2

1

5

3

4

6

7

Drilling 4 Holes on the Ceiling/ Wall and Fixing 

the Anchor Bolts

To install the ceiling mount bracket, drill four 

holes (6mm diameter/50mm depth) on the 

ceiling and insert the anchor bolts into the 

hole.

Fixing the Ceiling Mount Bracket

1. Drill a hole (20mm diameter) on the pipe of 

     the bracket to pass the cables. 

2. On the fixed anchor bolts, attach the rubber 

    gasket and screw the ceiling mount bracket.

Fixing the Surface Mount Bracket

Pass the cables through the hole of the surface 

mount bracket, screw the surface mount 

bracket to the ceiling mount bracket.

Connecting the Cables to the Terminal Block

Connect the cables to the terminal block and 

then put the terminal block in the slot of the 

main body.

Connecting the Terminal Block

Put the terminal block connected to the cables 

in the slot of the main body.

Fixing the Main Body

Screw the main body to the surface mount 

bracket by screwing 4 lock-up screws.

Detaching the Protection Film

Detach the protection film from the dome 

cover after finishing all installation.

Rubber 

Gasket

Rubber 

Gasket

Disassemble the main body with the 

surface mount before installation the camera.

1

2

3

4

6

7

5

Installation Using Sunshield Dome*

Installation Using Surface Mount Bracket

2

Alarm Output

- It connects to the alarm lights, siren or lamps, 

  and it is activated according to the OSD menu 

  setting.

- There are 1 Alarm Output and it is relay 

  contact type. Therefore, you do not have to 

  care about polarity, AC/DC, and isolations 

  between channels. Care must be taken for the 

  power capacity of relay contact type.

- The sensor types are normal open and 

  normal close.

Alarm Input/Sensor

- It connects to IR sensor, IrDA sensor or door 

  switch.  If the sensor is activated, it can activate 

  to move camera to the specific angle and to 

  connect the alarm device.

- A cable of the sensor should connect to input 

  1 or 2, and the other should be connected to

  ‘COM’ slot.

- The sensor types are normal open and 

  normal close.

1

Alarm Output Slot

RS-485 Slot

Alarm Input/Sensor Slot

Power Input Slot 

COM

1

2

Keyboard 

Controller/DVR

Camera 1 Camera 2 Camera n

~

3

RS-485 Communication (Keyboard Controller/

DVR)

For PTZ control, connect this line to keyboard 

and DVR. 

To control multiple cameras at the same time, 

RS-485 communication lines of them are 

connected in parallel as shown below.

Power

- Please check the correct rated power. 

- The rated power is marked on the bottom of 

  the camera.

4

COM

4

3

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

Rubber Gasket

1

Wall Mount Option

Ceiling Mount Option

2

1

5

3

4

6

7

Drilling a Hole on the Ceiling and Fixing 

the Anchor Bolts

To install the ceiling mount bracket, drill four 

holes (6mm diameter/50mm depth) on the 

ceiling and insert the anchor bolts into the 

hole.

Fixing the Ceiling Mount Bracket

1. Drill a hole (20mm diameter) on the pipe of 

     the bracket to pass the cables. 

2. On the fixed anchor bolts, attach the 

     rubber gasket and screw the ceiling 

     mount bracket.

Fixing the Sunshield Dome

Pass the cables through the hole of the 

Sunshield Dome. Screw the Sunshield Dome to 

the ceiling mount bracket.

Connecting the Cables to the Terminal Block

Connect the cables to the terminal block and 

then put the terminal block in the slot of the 

main body.

Connecting the Terminal Block

Put the terminal block connected to the 

cables in the slot of the main body.

Fixing the Main Body

Screw the main body to the surface mount 

bracket by screwing 4 lock-up screws.

Detaching the Protection Film

Detach the protection film from the dome 

cover after finishing all installation.

Rubber 

Gasket

Disassemble the main body with the surface 

mount before installation the camera.

1

2

3

4

6

7

5

!

Accessories are optional and sold separately.

Ceiling Mount 

Option

Wall Mount 

Option

1. Before power is applied, please check the cables carefully.

2. The camera ID of the controller must be identical to that of the camera to be 

    controlled. The camera ID can be check in the system information of OSD menu.

3. If your controller supports multi-protocols, the protocol must be changed to 

    match to that of the camera.

4. If you changed camera protocol by changing DIP switch, the change will be 

    effective after you reboot the camera.

5. Since the operation method can be different for each controller available, refer 

    to the manual for your controller if camera cannot be controlled properly.

Check Points before Operation

Preset and Pattern Function Pre-check

Check how to operate preset, pattern, scan and group

function with keyboard controller/DVR in advance to operate

camera function using them.

(Refer to system keyboard manual)

Start OSD Menu

Using the OSD menu, preset, pattern, scan, group and alarm

input function can be configured for each application.

Enter ‘Preset key + 95’.

Auto Calibration

If the camera is continuously subjected to very 

high temperatures (over 50°C or 122°F) for a long 

period, the camera can lose focus and produce 

blurry images. In this case, it is recommended to 

turn on AUTO CALIBRATION by running preset 165.

If you execute AUTO CALIBRATION, the camera 

will calibrate its focus for 10 seconds every 24 

hours. To turn OFF this function, please run 

preset 166. 

!

Accessories are optional and sold separately.

Surface Mount 

Bracket

Rubber Gasket

Thank you for purchasing Digital Watchdog’s Super Speed Dome PTZ Outdoor Dome Camera.

Before installing the camera, please verify your model and read this guide carefully.

09192012

The following items are included with the PTZ camera 

9

8

Main Body + Surface Mount Bracket

9P Terminal Block

Rubber Gasket

Template Sheet

Manual CD

DWC-P12WM

Indoor Wall Mount 

(Not Included)

DWC-P12WMS

Sunshield Wall Mount 

(Not Included)

DWC-P39CNM

Corner Mount

(Not Included)

DWC-P39POLM

Pole Mount

(Not Included)

DWC-P12CM

Indoor Ceiling Mount*

DWC-P12CMS

Sunshield Ceiling Mount 

(Not Included)

PREPARATION

TEL: (866) 446-3595

www.Digital-Watchdog.com / [email protected]

Technical Support Hours: Monday-Friday 8:30AM to 8:00PM EST

INSTALLATION

3

5

7

 4

Analog PTZ Outdoor

Quick Start Guide

x

12 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interferenece at his own
expense.

To disconnect power from the mains, pull out the mains cord plug.  

When install the product, ensure that the plug is easily accessible. 

Version 1.01

INSTALLATION 

(SURFACE MOUNT)

INSTALLATION 

(INDOOR)

Screw & Plastic Anchor-4pcs

Torx Wrench

Quick Manual

Отзывы: