Accessories are optional and sold separately.
10
Camera Parts and ID Setup
Installation Using Ceiling / Wall Mount Bracket*
2
6
8
INSTALLATION
Terminal Block Connections
1
2
3
5
6
7
INSTALLATION
(OUTDOOR)
INSTALLATION
First Time Bootup and Initial Testing
Dome Cover
- Protects the camera module from outside environment.
- Do not detach protection film from the dome cover
before finishing all installation to protect
dome cover from scratches or dust.
Lockup Screw
Fixes main body to the surface mount bracket.
Fan
Fan for temperature control.
BNC Video Cable
Main video output cable.
9P Terminal Block Slot
9P terminal block that is connected with cables is
inserted in this slot.
LED & Reset Button
LED for active(yellow light), power(red light) status
and Reset button for reset camera.
ID Setup Switch
Specify the camera ID.
The ID number of the camera is set using binary
numbers.
- If you want to control a certain camera, you must
match the camera ID with ‘CAM ID’ setting of DVR or
keyboard controller.
- The range of Camera ID is 0~255.
- All cameras have a factory default Camera ID of 1.
- Camera ID will be effective without having to reboot
the camera.
¾” Pipe Mounting Hole
- This is used to pass the cables to the cameras.
- When water protection is needed, connect the ¾” pipe
through this hole, then pass the cables through the
pipe.
Mounting Hole (x4)
This is used to attach the surface mount bracket to the
ceiling.
Surface Mount Bracket
The camera’s main body protects the camera’s wires.
This part is required when installing the camera with
an Indoor Accessory.
2
1
5
3
4
6
7
8
9
Main Body
1
2
Bottom of Main Body
3
4
5
7
8
9
6
10
Drilling the Hole
on the Ceiling
Pass cables through
3/4” holes & mount
Bracket.
2
2
1
3
5
2
1
5
3
4
Rubber Gasket
Template Sheet
Disassemble the main body with the
surface mount before installation the
camera.
Drilling 4 Holes on the Ceiling
Using provided template sheet, drill a hole
(30mm diameter) on the ceiling panel to
pass cables.
Fixing the Surface Mount Bracket
Pass the cables through the ¾” pipe hole,
and screw the surface mount bracket to the
ceiling.
Rubber Gasket
- Before installing the gasket, the hole in the
center is to be cut by knife when only necessary.
Connecting the Cables and the Terminal Block
Connect the cables to the terminal block and
then put the terminal block in the slot of the
main body.
Fixing the Main Body
Screw the main body to the surface mount
bracket by screwing 4 lock-up screws.
Detaching the Protection Film
Detach the protection film from the dome
cover after finishing all installation.
4
2
1
5
3
4
6
7
Drilling 4 Holes on the Ceiling/ Wall and Fixing
the Anchor Bolts
To install the ceiling mount bracket, drill four
holes (6mm diameter/50mm depth) on the
ceiling and insert the anchor bolts into the
hole.
Fixing the Ceiling Mount Bracket
1. Drill a hole (20mm diameter) on the pipe of
the bracket to pass the cables.
2. On the fixed anchor bolts, attach the rubber
gasket and screw the ceiling mount bracket.
Fixing the Surface Mount Bracket
Pass the cables through the hole of the surface
mount bracket, screw the surface mount
bracket to the ceiling mount bracket.
Connecting the Cables to the Terminal Block
Connect the cables to the terminal block and
then put the terminal block in the slot of the
main body.
Connecting the Terminal Block
Put the terminal block connected to the cables
in the slot of the main body.
Fixing the Main Body
Screw the main body to the surface mount
bracket by screwing 4 lock-up screws.
Detaching the Protection Film
Detach the protection film from the dome
cover after finishing all installation.
Rubber
Gasket
Rubber
Gasket
Disassemble the main body with the
surface mount before installation the camera.
1
2
3
4
6
7
5
Installation Using Sunshield Dome*
Installation Using Surface Mount Bracket
2
Alarm Output
- It connects to the alarm lights, siren or lamps,
and it is activated according to the OSD menu
setting.
- There are 1 Alarm Output and it is relay
contact type. Therefore, you do not have to
care about polarity, AC/DC, and isolations
between channels. Care must be taken for the
power capacity of relay contact type.
- The sensor types are normal open and
normal close.
Alarm Input/Sensor
- It connects to IR sensor, IrDA sensor or door
switch. If the sensor is activated, it can activate
to move camera to the specific angle and to
connect the alarm device.
- A cable of the sensor should connect to input
1 or 2, and the other should be connected to
‘COM’ slot.
- The sensor types are normal open and
normal close.
1
Alarm Output Slot
RS-485 Slot
Alarm Input/Sensor Slot
Power Input Slot
COM
1
2
Keyboard
Controller/DVR
Camera 1 Camera 2 Camera n
~
3
RS-485 Communication (Keyboard Controller/
DVR)
For PTZ control, connect this line to keyboard
and DVR.
To control multiple cameras at the same time,
RS-485 communication lines of them are
connected in parallel as shown below.
Power
- Please check the correct rated power.
- The rated power is marked on the bottom of
the camera.
4
COM
4
3
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
Rubber Gasket
1
Wall Mount Option
Ceiling Mount Option
2
1
5
3
4
6
7
Drilling a Hole on the Ceiling and Fixing
the Anchor Bolts
To install the ceiling mount bracket, drill four
holes (6mm diameter/50mm depth) on the
ceiling and insert the anchor bolts into the
hole.
Fixing the Ceiling Mount Bracket
1. Drill a hole (20mm diameter) on the pipe of
the bracket to pass the cables.
2. On the fixed anchor bolts, attach the
rubber gasket and screw the ceiling
mount bracket.
Fixing the Sunshield Dome
Pass the cables through the hole of the
Sunshield Dome. Screw the Sunshield Dome to
the ceiling mount bracket.
Connecting the Cables to the Terminal Block
Connect the cables to the terminal block and
then put the terminal block in the slot of the
main body.
Connecting the Terminal Block
Put the terminal block connected to the
cables in the slot of the main body.
Fixing the Main Body
Screw the main body to the surface mount
bracket by screwing 4 lock-up screws.
Detaching the Protection Film
Detach the protection film from the dome
cover after finishing all installation.
Rubber
Gasket
Disassemble the main body with the surface
mount before installation the camera.
1
2
3
4
6
7
5
!
Accessories are optional and sold separately.
Ceiling Mount
Option
Wall Mount
Option
1. Before power is applied, please check the cables carefully.
2. The camera ID of the controller must be identical to that of the camera to be
controlled. The camera ID can be check in the system information of OSD menu.
3. If your controller supports multi-protocols, the protocol must be changed to
match to that of the camera.
4. If you changed camera protocol by changing DIP switch, the change will be
effective after you reboot the camera.
5. Since the operation method can be different for each controller available, refer
to the manual for your controller if camera cannot be controlled properly.
Check Points before Operation
Preset and Pattern Function Pre-check
Check how to operate preset, pattern, scan and group
function with keyboard controller/DVR in advance to operate
camera function using them.
(Refer to system keyboard manual)
Start OSD Menu
Using the OSD menu, preset, pattern, scan, group and alarm
input function can be configured for each application.
Enter ‘Preset key + 95’.
Auto Calibration
If the camera is continuously subjected to very
high temperatures (over 50°C or 122°F) for a long
period, the camera can lose focus and produce
blurry images. In this case, it is recommended to
turn on AUTO CALIBRATION by running preset 165.
If you execute AUTO CALIBRATION, the camera
will calibrate its focus for 10 seconds every 24
hours. To turn OFF this function, please run
preset 166.
!
Accessories are optional and sold separately.
Surface Mount
Bracket
Rubber Gasket
Thank you for purchasing Digital Watchdog’s Super Speed Dome PTZ Outdoor Dome Camera.
Before installing the camera, please verify your model and read this guide carefully.
09192012
The following items are included with the PTZ camera
9
8
Main Body + Surface Mount Bracket
9P Terminal Block
Rubber Gasket
Template Sheet
Manual CD
DWC-P12WM
Indoor Wall Mount
(Not Included)
DWC-P12WMS
Sunshield Wall Mount
(Not Included)
DWC-P39CNM
Corner Mount
(Not Included)
DWC-P39POLM
Pole Mount
(Not Included)
DWC-P12CM
Indoor Ceiling Mount*
DWC-P12CMS
Sunshield Ceiling Mount
(Not Included)
PREPARATION
TEL: (866) 446-3595
www.Digital-Watchdog.com / [email protected]
Technical Support Hours: Monday-Friday 8:30AM to 8:00PM EST
INSTALLATION
3
5
7
4
Analog PTZ Outdoor
Quick Start Guide
x
12
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interferenece at his own
expense.
To disconnect power from the mains, pull out the mains cord plug.
When install the product, ensure that the plug is easily accessible.
Version 1.01
INSTALLATION
(SURFACE MOUNT)
INSTALLATION
(INDOOR)
Screw & Plastic Anchor-4pcs
Torx Wrench
Quick Manual