CT-5320F/CT-5640F Fixed Thermal Camera QIG
18
Item
Description
AGC
Automatic Gain Control (AGC) adjusts the gain and
level of the entire scene in real-time. From the drop-
down menu, select a mode:
Freeze –
Turns off/freezes AGC at its current
level.
Auto
– provides an image with optimum
average contrast and brightness.
ICE
– Enhanced gain control/Image Contrast
Enhancement (ICE) that prevents the
darkening of scenes and reduces detector
noise when hot objects appear in low-
contrast indoor scenes. It also amplifies
detector noise to enhance images of high-
contrast outdoor scenes.
ICE
Move the slider to adjust the strength of the AGC/ICE
settings. The range is from 1-7. The higher the
number, the better the picture. The default is 4.
Contrast
Move the slider to adjust the contrast. The range is
from 1-100. The higher the number, the higher the
contrast. The default is 50.
Brightness
Move the slider to adjust the brightness. The range is
from 1-100. The higher the number, the brighter the
picture. The default is 50.
Polarity
Enables you to select how to display hot and cold
pixels. Select one of the following settings:
White Hot – Hot pixels are shown as white
and cold pixels are shown as black.
Black Hot – Hot pixels are shown as black
and cold pixels are shown as white.
Non
Uniformity
Correction
(NUC)
Normally, an NUC is performed automatically to
compensate for temperature variations. Click this
button to manually force a Non Uniformity Correction.
The NUC interval can also be set using the
maintenance/camera functions menu.