Camera Dimensions, Settings and Wiring
5
3.2.1
Communication Dip Switch Settings
Factory default settings for the communication dip switches are as follows:
Communication Switch
SW 1
RS-485 Setting
SW 2
SW 3
Termination
SW 4
Reserved
SW 5
Factory Default Reset
SW 6
Reserved
Figure 4 - Camera Dip Switch Settings
Switches 1 and 2 are used to set the communication protocol. The factory default setting is half-
duplex (both switches in the ON position). Do NOT change this setting.
Note:
Verify that the encoder is also set to half-duplex communication.
Do NOT change the setting of switches 3, 4, and 6.
Switch 5 is used to reset factory defaults. Verify that this is set to OFF. Factory default settings can
be reset in the field using either the web interface or by manually moving Switch 5.
Note:
1.
If you perform a factory default
from the web interface
, switch 5 can be in the
OFF position.
2.
To reset factory defaults
without a PC
, unplug the power, set switch 5 to ON,
and reconnect the power. The camera resets itself. Unplug the power. Set
switch 5 to OFF and reconnect the power.
3.2.2
Camera Control Protocol Switch
Verify that the camera control protocol switch is preset to 12 in order to operate with the DVTEL
XPVA assembly. This setting should not be changed.
3.2.3
Camera ID Setting
Verify that the Camera ID default setting is 001.
Figure 5 - Camera ID Setting