DVP TDC 150 Скачать руководство пользователя страница 23

 

 

User and maintenance manual

 

EN

 

TSC - TDC

 

 

 

22

 

 

8702040 – 14/01/2019 – R.7 

www.dvp.it 

 

DISMANTLING    

 

The side channel turbine must be dismantled by authorised technicians.  
Metal parts can be disposed of as scrap metal. 
All materials deriving from demolition must be disposed of according to regulations in the country where the side 
channel turbine will be demolished. 

 

 

HAZARD 
Disposal  operations  involve  risks  of  cutting,  shavings  protection,  entanglement,  contact  with 
moving parts and contact with chemicals. 
Operators should use the appropriate personal protective equipment. 

 
 
 
 
 

TROUBLESHOOTING 

 

DAMAGE 

CAUSE 

REMEDY 

The turbine motor does not start 

up, the start up noise is muffled 

and metallic. 

One of the electric motor's power 

supply phases is not connected.  

Check and correct.  

The turbine's impeller is obstructed by 

dirt.  

Contact Service Department 

A bearing is blocked or defective.  

Contact Service Department 

Short-circuit in the electric motor 

winding.  

Contact Service Department 

Intervention of the electric motor 

protection system.  

 

The electric motor's protection 

fuses burn.  

 

The current absorbed by the 

electric motor is too high.  

The electric motor is overloaded.  

Check and correct.  

The turbine's impeller is blocked.  

Contact Service Department 

The working pressure or vacuum are 

greater than the acceptable levels.  

Check the installation and working of 

the safety valves.  

Drop in voltage.  

Check if the connection cables are 

suitable for the electric motor's power.  

Blocked piping.  

Check and correct.  

Dirty intake filter.  

Check and correct.  

The turbine does not produce 

vacuum or pressure in the 

system. 

The machine's rotating direction is 

wrong.  

Check and correct.  

Leaks in the system. 

Check and correct.  

System's gaskets damaged.  

Check and correct.  

Turbine's impeller blocked by dirt.  

Contact Service Department 

Unusual noises coming from the 

turbine.  

Deteriorated rolling bearings.  

Contact Service Department 

Dirty silencers.  

Check and replace (see 6.2.6). 

Dust or process residues on the 

turbine's impeller.  

Contact Service Department 

Vibration transmission from the system.  

Check and correct.  

 

 

 

Содержание TDC 150

Страница 1: ...VACUUM TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions SIDE CHANNEL BLOWERS TSC TDC...

Страница 2: ...4 3 TRANSPORT AND HANDLING 13 4 4 STORAGE 13 4 5 ENVIRONMENTAL CONDITIONS 13 4 6 TURBINE INSTALLATION 14 4 7 USER SYSTEM 14 4 8 CONNECTION 14 4 8 1 INTAKE AND OUTLET CONNECTION 15 4 8 2 ELECTRIC CONN...

Страница 3: ...5118897101 Fx 3905118897170 e mail info dvp it web site http www dvp it Please always include the following information in all communications regarding the turbine turbine model and serial number year...

Страница 4: ...y safety requirements in particular it is mandatory that personnel are equipped with personal protective equipment in relation to the activities that must be performed 1 6 IDENTIFICATION PLATE The sid...

Страница 5: ...ke and outlet silencers it is possible to access the rotating rotor Never insert your hands or any kind of object through the openings This hazard also exists when the machine is not moving when it is...

Страница 6: ...n of the side channel turbine in order to avoid those in charge of works being directly hit by parts or bits of parts flying through the fan cover casing due to the cooling fan breaking 2 3 PICTOGRAMS...

Страница 7: ...s other than those indicated in the tables shown in point 3 3 of this manual Do not use the turbine in an explosive or aggressive atmosphere or in an atmosphere with a high concentration of dust or oi...

Страница 8: ...115 175 1 1 2 G 284 273 285 0 TSC 210 260 298 115 195 123 250 M8 4 47 175 339 14 120 200 2 G 320 322 332 0 TSC 310 290 332 140 180 113 250 M8 5 50 195 382 14 125 240 2 G 370 362 383 0 TSC 310 1 290 3...

Страница 9: ...EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 52 55 58 61 63 64 70 73 52 55 58 61 63 64 64 65 64 65 Weight kg 7 12 18 27 5 7 12 17 5 19 19 Intake Outlet G 1 1 1 4 1 1 2 2 1 1 1 4 1 1 2 1 1 2 1 1 2 Required w...

Страница 10: ...78 74 79 76 81 76 81 Weight kg 26 5 37 5 40 41 83 5 83 5 90 122 133 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 2 1 2 4 4 Required workplace temperature C 0 40 Storage transport room temperature C 20 50 MAX...

Страница 11: ...13 79 250 M8 5 50 195 TDC 310 1 290 332 140 180 252 252 218 250 M8 5 98 195 TDC 550 365 420 280 315 307 193 139 350 M12 30 96 280 TDC 550 1 365 420 280 315 307 308 254 350 M12 30 121 280 MODEL H2 HT L...

Страница 12: ...A 50Hz dB A 60Hz 60 66 66 69 60 66 66 69 66 69 Weight kg 18 31 18 30 32 5 Intake Outlet G 1 1 4 1 1 2 1 1 4 1 1 2 1 1 2 Required workplace temperature C 0 40 Storage transport room temperature C 20 50...

Страница 13: ...0 600 Noise level UNI EN ISO 2151 K 3dB dB A 50Hz dB A 60Hz 74 77 74 77 75 79 75 79 76 81 76 81 Weight kg 43 5 45 56 58 120 149 Intake Outlet G 2 2 2 2 2 1 2 2 1 2 Required workplace temperature C 0 4...

Страница 14: ...handling operation must be performed by qualified and experienced personnel It is strictly forbidden to lift the turbine in any way other than that foreseen The side channel turbine can be raised and...

Страница 15: ...ironmental conditions or causing discomfort to personnel In order to avoid vacuum or overpressure excesses fit an intake or compression outlet safety valve that allows you to comply with the levels sh...

Страница 16: ...are not transmitted on the turbine s attachments WARNING Use an intake filter especially if the turbine works with unclean air flows 4 8 2 ELECTRIC CONNECTION WARNING Check that voltage and frequency...

Страница 17: ...e the electric connection box as shown on the side Heat protector specifications NC contact type Intervention temperature 130 5 C Electric contact flow 250Vac 1 A Heat protector connection layout 1 Co...

Страница 18: ...ors and or protections and or closure valves Check that the adjustment of the motor protection corresponds with the motor s nominal current indicated on the relative plate Check the correct functionin...

Страница 19: ...the power supply to the motor If the turbine is to be turned off let it run with the intake open for about 30 minutes first This will eliminate any moisture inside the intake chamber and avoid the oxi...

Страница 20: ...ual HAZARD All maintenance work must be carried out with the turbine disconnected from the power supply and measures must be adopted to prevent it being reconnected Only open the terminal board after...

Страница 21: ...y cloth for the container while for the cartridge blowing compressed air aimed in the opposite direction to the conveyed flow s filtering direction that is from the inside outwards Do not use fluids o...

Страница 22: ...below you will need to grease the rolling bearings again on the side channel impeller Favourable storage conditions see point 3 3 of this manual 4 years Unfavourable storage conditions high humidity...

Страница 23: ...r winding Contact Service Department Intervention of the electric motor protection system The electric motor s protection fuses burn The current absorbed by the electric motor is too high The electric...

Страница 24: ...User and maintenance manual EN TSC TDC 23 8702040 14 01 2019 R 7 www dvp it...

Страница 25: ...User and maintenance manual EN TSC TDC 24 8702040 14 01 2019 R 7 www dvp it...

Страница 26: ...t appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance...

Страница 27: ...Cod 8702040 14 01 2019 R 7 EN D V P Vacuum Technology s p a Via Rubizzano 627 40018 San Pietro in Casale BO Italy Ph 3905118897101 Fx 3905118897170 www dvp it...

Отзывы: