12
5.1.2 “N” Field Integration; 4 values of “N”, Two-speed Electronic Shutter, Pulse
Driven Integration & Asynchronous Reset:
Mode
Reset pin 17
“N” Field Integration (N = 2) Integ. period = 33.33ms
“N” Field Integration (N = 4) Integ. period = 66.66ms
“N” Field Integration (N = 6) Integ. period = 99.99ms
“N” Field Integration (N = 12) Integ. period = 199.99ms
Shutter (1/1000 sec, Integration period = 1.0ms)
inactive
Shutter (1/2000 sec, Integration period = 0.5ms)
Pulse driven integ. (Reset duration sets Integ. period)
1
1
1
Normal (Default: 1/60sec, Integration period = 16.66ms)
Since all Mode Control (MC) and RESET pins are internally pulled up, the unit defaults to the
normal (1/60sec) mode until a pin is pulled LOW (via a computer, or by connecting it to ground).
5.2 ELECTRONIC SHUTTERING MODE:
For integration periods less than 1/1000 sec, the following process (called electronic
shuttering) is carried out.
At the beginning of the Vertical Blanking Interval, the CCD is flushed by means of two charge
transfers. This takes approximately 140
µ
sec. After the two "clearing" transfers, the Integration
Period begins. Before the end of the Vertical Blanking Interval, however, a "readout" transfer
takes place. The period between the two clearing transfers and the third (readout) transfer is the
Integration Period; it's duration is dependent on the user selected speed of the shutter (1/1000
sec or 1/2000 sec).
The following active field is used to read out the charge that was integrated in the Imaging Area
during the Integration Period. By completing the entire Integration Period within the Vertical
Blanking Interval, the electronic shuttering process can be done without disturbing the normal
sync and timing of the camera.
Shutter Mode
Readout EVEN FIELD
Shuttered Image
TRANSFER PULSE
INTEG.
ODD
FIELD
CCD FLUSH PERIOD = 140us
Readout ODD FIELD
Shuttered Image
ODD FIELD
1/60 sec
EVEN FIELD
1/60 sec
INTEG.
EVEN
FIELD
INTEG.
ODD
FIELD
SHUTTER DURATION = 1/1000s OR 1/2000s
EVEN FIELD
VERTICAL
BLANKING
INTERVAL
VERTICAL
BLANKING
INTERVAL
VERTICAL
BLANKING
INTERVAL
Figure 5-1: Shutter Mode Timing Diagram
Содержание DigitEyes Series
Страница 14: ...9 Figure 4 3 TC 245 Gate Level Drawing Texas Instruments 1994 ...
Страница 61: ...56 12 Appendix D Camera Mechanical Drawings Figure 12 1 Camera Mechanical Drawings ...
Страница 63: ...58 Figure 13 2 Camera Noise Spectrum Min Gain Bandwidth 10kHz to 4 2MHz ...
Страница 64: ...59 Figure 13 3 Camera Noise Spectrum Max Gain Bandwidth 100kHz to 4 2Mhz ...
Страница 65: ...60 Figure 13 4 Camera Noise Spectrum Max Gain Bandwidth 10kHz to full ...