background image

 
 

     

 

 

                                               02/03/16 - AC - Rev.1 

 

 

 

5/11 

 

5.

 

MAINTENANCE MADE BY QUALIFIED OPERATOR  
 

5.1

 

SCHEME OF THE FIRE EXTINGUISHERS   

 

Models :  9D-58-A 

(Class A)  

/  9D-58-A 

(Classes  A  F )  

/

  

9D-58-AB 

               

 

N.   Description 

 

 

Safety seal 

 

 

Safety pin 

 

 

Wall bracket 

 

 

Ceck valve 

 

 

Plug ceck valve 

 

 

Safety valve 

 

 

Valve 

 

 

O-ring 

 

 

Valve stem assembly 

 

 

10  Cylinder 

 

 

11  Spring stem 

 

 

12  Extinguishing agent 

 

 

13  Tube holder 

 

 

14  Hose 

 

 

15  Dip tube 

 

 

16  Label 

 

 

17  Nozzle 

 

 

18  Filter dip tube 

 

 

19  Base 

 

 

 

 

Models :  9D-34-A 

(Class A)  

/  9D-34-A 

(Classes  A  F )  

/

  

9D-34-AB 

 

 

N.   Descrizione 

 

 

Wall bracket  

 

 

Safety seal 

 

 

Safety pin 

 

 

Plug ceck valve 

 

 

Ceck valve 

 

 

Valve 

 

 

O-ring 

 

 

Valve stem assembly 

 

 

Cylinder 

 

 

10  Spring stem 

 

 

11  Extinguishing agent 

 

 

12  Tube holder 

 

 

13  Hose 

 

 

14  Dip tube 

 

 

15  Label 

 

 

16  Nozzle 

 

 

17  Filter dip tube 

 

 

18  Base 

 

 

 
 
 
 
 
 
 
 

Содержание 9D-34-A

Страница 1: ...this document is prohibited 02 03 16 AC Rev 1 INSTRUCTIONS USE AND MAINTENANCE PORTABLE FIRE EXTINGUISHERS WATER ADDITIVE PERMANENT PRESSURE Models 9D 58 A Class A 9D 58 A Classes A F 9D 58 AB 9D 34 A...

Страница 2: ...FIRE EXTINGUISHERS 5 5 2 GENERAL INFORMATION 6 5 3 SAFETY PRECAUTIONS FOR MAINTENANCE OPERATOR 6 5 4 RECHARGE OF THE FIRE EXTINGUISHERS 6 5 5 TAG OF MAINTENANCE 7 5 6 REVISION 7 5 7 SERVICE LIFE OF A...

Страница 3: ...a temperature not lower than 0 C and not higher than 60 C limit temperatures of use On Class B fires maintain a certain distance with the outbreaks 4 5 m to avoid liquid splashes Do not start from the...

Страница 4: ...ers It is recommended to the user or his representative to provide at regular intervals for inspection work in order to ensure that each extinguisher is located where it is indicated with a visible si...

Страница 5: ...ring 9 Valve stem assembly 10 Cylinder 11 Spring stem 12 Extinguishing agent 13 Tube holder 14 Hose 15 Dip tube 16 Label 17 Nozzle 18 Filter dip tube 19 Base Models 9D 34 A Class A 9D 34 A Classes A...

Страница 6: ...ance and charging procedures may temporarily reduce the effectiveness of preventive measures implemented at its headquarters for fire protection Therefore you must observe the following points a accor...

Страница 7: ...of revision The maintenance program is designed to make sure that portable fire extinguishers are always in working during the entire period of use All extinguishers must be subject to a revision in a...

Страница 8: ...raph 5 3 2 to remove the valve from the cylinder 7 To empty a portable fire extinguisher Pour the initial charge into a clean container and check whether the charge can be reused If there is debris re...

Страница 9: ...nguisher in accordance with the instructions of the table in paragraph 5 8 1 8 Insert a new plug and a new safety seal and fill the tag maintenance extinguisher NOTE 1 The extinguishing agent foam mus...

Страница 10: ...ring the other phases of the life time of a fire extinguisher PHASE EVENT RISK PREVENTIVE MEASURES CORRECTIVE ACTIONS TRANSPORT AND INSTALLATION Extinguisher damaged deformations due to impacts RELEAS...

Страница 11: ...ated clothing and shoes before reuse After contact with eyes In case of contact with eyes rinse promptly and thoroughly with water and seek medical advice After swallowing Remove victim from exposure...

Отзывы:

Похожие инструкции для 9D-34-A