Shut off the disconnect panel and lock out all electrical
power to the dust collector before performing any
service work.

Loosen check valve (white plastic part) connected to
brass tee threaded into air manifold reservoir to
completely relieve air pressure prior to performing any
service work on the air pulse cleaning system (refer to
Figure 8).

The Supra-Conic

®

dust collector is supplied with a self-

contained air pulse cleaning system which has been
factory installed by UAS.  The air pulse cleaning system
consists of the following major components: air
compressor, diaphragm valve, pressure switch with
unloader valve, check valve, interconnecting tubing and
fittings, air manifold reservoir, printed circuitboard
controller card, and conical filter assembly. The air pulse
cleaning control system requires 500 watts of 100-120V,
single-phase, 50/60 hertz power supply to operate.

The dust collector may be configured without a built-in air
compressor, in which the customer is to supply the clean,
dry, oil-free compressed air to the air manifold reservoir.

!

WA R N I N G

5.  OPERATION

5.1  START-UP

Never operate dust collector without the blower
compartment bolt-on panel being installed.

Shut off unit disconnect and lock out all electrical 
power to the dust collector prior to performing 
service work.

UNIT BLOWER (FAN)

Inspect the installation area and make certain no tools,
parts, etc. have been left anywhere on or inside the
Supra-Conic

®

dust collector.  Check blower discharge to

make certain it is free from all debris.

Start motor/blower and check for proper rotation.  A
rotation arrow is located in the blower compartment
beside the fan wheel.  All blower wheels rotate in a
clockwise rotation as viewed from the driven end (motor
end with motor cooling fan).  If the blower is rotating in
the opposite direction, disconnect the power to the motor
starter.  For 3-phase power, interchange any two power
wires to the motor at the load side of the motor starter
contactor (for single-phase power, refer to motor
nameplate for which two wires to interchange at motor
junction box), engage starter disconnect, start blower
and recheck rotation.

NOTE:

Proper blower rotation is required to move the
designed amount of air. A blower rotating in the
incorrect direction will only move about 40% of
design airflow and cause the fan motor to pull
excessive running load amps.  Running blower in
incorrect rotation for an extended period of time
will cause fan motor damage and reduce life of
motor/blower.

PC CONTROLLER BOARD

The Supra-Conic

®

dust collector is equipped with a

printed circuitboard (PC) controller card which controls
the air pulse cleaning cycle.  Refer to Figure 7 for PC
board layout and fuse information.

The PC controller card is equipped with four board LED
lights which can be seen through the electrical enclosure
lid.  The four LED lights indicate the following conditions:

FAULT –

Activates after a pulse valve or pressure

switch failure

PULSE –

Indicates when pulse valve is energized

SYSTEM –

The LED continuously illuminates to indicate
the air pulse cleaning system has been

energized.
The LED flashes to indicate the pulse cycle is
sequencing, allowing the pulse valve to
activate.

COMPRESSOR – 

Indicates the compressor is running.

!

WA R N I N G

4.9  SELF-CONTAINED COMPRESSED AIR

CLEANING SYSTEM

Содержание SUPRA-CONIC

Страница 1: ...SUPRA CONIC Cartridge Dust Collector Installation and Operation Manual ...

Страница 2: ...tion available when contacting UAS UAS ORDER ________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL ________________________________________________________________ CARTRIDGE FILTER PART ____________________________________________________ SYSTEM ACCESSORIES ___________________________________________...

Страница 3: ...l Air Pulse Cleaning Control System and Magnetic Motor Blower Starter Control Package 7 4 4 4 Electrical Air Pulse Cleaning Control System Less Air Compressor with Customer Supplied Motor Blower Starter Controls 7 4 4 5 Electrical Air Pulse Cleaning Control System Less Air Compressor with Manual Motor Blower Starter Controls 8 4 4 6 Combination Electrical Air Pulse Cleaning Control System Less Air...

Страница 4: ...PTIONAL ACCESSORIES AND INSTALLATION INSTRUCTIONS 20 7 1 Hopper Assembly 20 7 2 Magnehelic Gage 21 7 3 Caster Assembly SC600 and SC1700 Models only 21 7 4 ASHRAE and HEPA Afterfilter Assembly 21 7 5 Downdraft Bench Assembly SC1700 model only 21 7 6 Open Bin Vent Assembly 21 7 7 Inlet Gate Assembly 29 7 8 Pneumatic Valve Assembly Kit 29 7 9 Remote Blower Start Stop Assembly 29 7 10 Dust Re Entrainm...

Страница 5: ...lammable cleaners Do not collect emissions which are explosive Keep flammable materials and vapors such as gasoline away from air cleaner The unit should be inspected frequently and dirt removed to prevent excessive accumulation which may result in flash over or fire damage When collecting emissions from spark producing process es care must be taken to reduce any potential fire haz ards System des...

Страница 6: ...elease from the pleated filter design The dust collector is designed for automatic downtime filter cleaning by means of a built in compressed air system refer to Figure 2 There are two primary modes of operation the air filtering operation and filter cleaning cycle refer to Figure 3 2 3 AIR FILTERING OPERATION The Supra Conic is a compact high efficiency vertically orientated dust collector equipp...

Страница 7: ...Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector 2 United Air Specialists Inc FPO Use new diagram provided ...

Страница 8: ...Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector 3 United Air Specialists Inc ...

Страница 9: ...Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector 4 United Air Specialists Inc ...

Страница 10: ...t drawer SC3400 w 30 gallon 114 liter drum hopper assembly SC3400 w 55 gallon 208 liter drum hopper assembly Motor Blower HP kW 1 5 1 1 3 2 2 7 5 5 5 Filter Area FT2 M2 70 6 5 192 17 8 384 35 7 Filter Quantity 1 1 2 Valve Quantity 1 1 2 Unit Weight LBS KG 283 128 385 175 395 179 520 236 550 249 685 311 838 380 859 390 Maximum Sound Power Noise Level dB 5dB 5 ft 1 5M 73 79 85 usually reinforced Ref...

Страница 11: ...or starter package configured to either Figure 4 5 or 6 in accordance with local electrical codes regulations and directives All electrical work should be performed by a qualified electrician in accordance with local electrical codes regulations and directives De energize and disconnect electrical power before installing or servicing any electrical equipment Refer to Figures 4 5 and 6 for wiring s...

Страница 12: ...single phase 115V or 230V manual motor starter to operate the blower fan motor assembly This configuration requires two power supplies one 120V or 230V single phase 50 60 hertz power supply for blower fan motor assembly and one 120V single phase 50 60 hertz power supply for electrical air pulse cleaning control system Refer to Figures 5 and 6 for wiring schematics 4 4 3 COMBINATION ELECTRICAL AIR ...

Страница 13: ...llector above the air manifold reservoir The 100 120V single phase power supply must be connected to the PC board terminals L N G E L designates line power connection N designates neutral connection and G E designates earth ground connection The manual motor starter is pre wired to the blower fan motor assembly and is installed on the rear surface of the dust collector next to the 8 1 2 H 22cm x 7...

Страница 14: ...9 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 15: ...10 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 16: ...11 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 17: ...12 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 18: ...te is shipped loose along with fasteners for connecting the outboard plate to the Supra Conic inner base flange A dimension sheet and installation instruction drawing are provided with the bin vent package 4 6 DRUM LID KIT INSTALLATION FOR HOPPER ASSEMBLIES Remove the drum lid kit package from its shipping carton Place the drum lid on the 5 gallon 19 liter pail 30 gallon 114 liter shortened drum o...

Страница 19: ...14 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 20: ...tain it is free from all debris Start motor blower and check for proper rotation A rotation arrow is located in the blower compartment beside the fan wheel All blower wheels rotate in a clockwise rotation as viewed from the driven end motor end with motor cooling fan If the blower is rotating in the opposite direction disconnect the power to the motor starter For 3 phase power interchange any two ...

Страница 21: ...to complete 6 The second pulse cleaning operation is now energized The diaphragm valve s will activate for 1 second pulse LED will illuminate during pulse discharge operation The second pulse multi cycle downtime cleaning operation is now complete The system LED will now stop flashing and de energize indicating cleaning system is complete For the third pulse multi cycle downtime cleaning configura...

Страница 22: ...ads 93 100 PSIG 6 4 6 9 BAR DUST STORAGE CONTAINER Make certain the dust drawer is in place For units with a hopper assembly make certain all connections are airtight and the dust drum or pail is in place If the dust collector has a slide gate make certain it is open MAGNEHELIC GAGE KIT If the dust collector has been ordered with a field installed Magnehelic Gage shipped loose Magnehelic Gage Kit ...

Страница 23: ... to the controller card is de energized Toggle Switch SW2 can be configured to the following settings for the various downtime pulses for built in air compressor SW2 single downtime pulse SW2 two downtime pulses SW2 three downtime pulses Toggle Switch SW2 can be configured to the following settings for the various downtime pulses for customer supplied compressed air SW2 single downtime pulse SW2 t...

Страница 24: ... collector 6 Disposal of collected dust must be according to state and local environmental regulations 6 1 CARTRIDGE FILTER REMOVAL AND REPLACEMENT Authentic Supra Conic cartridge filters are the only replacement filters that will provide the high level of performance expected from the Supra Conic dust collector Replacement cartridge filters should be ordered when the differential pressure across ...

Страница 25: ... proper fan life Grease motor every 3 600 hours with high grade ball and roller bearing grease Recommended grease is Chevron SRI 2 Periodically inspect the blower wheel coupling mounting bolt for tightness Retighten as necessary to ensure fan wheel does not loosen and come in contact with the inlet bell Clearance between fan wheel and inlet bell should be kept at flush _0 25 6mm 6 5 SERVICING OPTI...

Страница 26: ...embly must be securely anchored to the floor surface to prevent the unit from tipping over resulting in possible equipment damage and injury to personnel C A U T I O N C A U T I O N 7 2 MAGNEHELIC GAGE An optional Magnehelic gage package can be installed on the Supra Conic dust collector to display the differential pressure across the filter assembly The gauge can be either field mounted installed...

Страница 27: ...22 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 28: ...23 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 29: ...24 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 30: ...25 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 31: ...26 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 32: ...27 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 33: ...28 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector ...

Страница 34: ...ssembly kit layout 7 9 REMOTE BLOWER START STOP ASSEMBLY A remote blower start stop pushbutton station is available for field installation on Supra Conic assemblies configured with a combination magnetic motor blower starter control package supplied by UAS The combination magnetic motor blower starter control package must be configured and wired in accordance with Figures 4 and 5 The customer is r...

Страница 35: ...board controller card across terminals labeled SW PRESS Refer to Figure 7 for printed circuitboard controller card terminal block locations The pressure switch with unloader valve air compressor brass tee fitting and check valve are not required for the Supra Conic air pulse cleaning system to operate when the unit is configured without an air compressor supplied by UAS i e customer to provide pla...

Страница 36: ... proper voltage on each phase Check and correct internal motor wiring for proper connections based on the incoming line voltage Check for proper motor starter overload rating against full load amps on the motor nameplate Adjust or replace overloads as required Check for proper blower rotation Swap motor leads to reverse blower rotation Ensure drum is properly sealed against drum lid package Ensure...

Страница 37: ...ter blower shutdown Inspect and clean all hoods or other machine connections Verify compressor is supplying 93 PSIG 6 5 BAR of air to air reservoir manifold for downtime filter cleaning operation Adjust pressure switch to allow 93 PSIG 6 5 BAR of air in air reservoir manifold Check incoming 100 120V power to cleaning system electrical PC controller card Check for blown fuse s on clean ing system P...

Страница 38: ...using soap solu tion Correct all leaks as found Reset pressure switch to cut out at 93 PSIG 6 5 BAR Replace pressure switch Clean and or replace check valve locat ed below the pressure switch Verify valve solenoid is energized by watching PULSE LED on PC controller card If LED fails to illuminate replace controller card If LED illuminates replace valve solenoid Verify air compressor is energized b...

Страница 39: ...34 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector FIGURE 19 SUPRA CONIC SERIES EXPLODED VIEW 9 ILLUSTRATED PARTS ...

Страница 40: ...z Operation 1 32 0306 19mm Dia Motor Shaft 50 Hz Operation 1 8 select Fan Inlet Bell 32 0305 Match With Blower Wheel P N 32 0304 1 32 0307 Match With Blower Wheel P N 32 0306 1 9 select Bushing Split Taper 31 0265 0 625 Dia 1 n a 19mm Dia Supplied With Blower Wheel 10 39 0255 Lower Hinge 1 set 11 39 0256 Upper Hinge 1 set 12 39 0291 Filter Mounting Knobs 2 13 10 9203 3 Exhaust Cover Plate 1 14 n a...

Страница 41: ...on 1 32 0300 38mm Dia Motor Shaft 50 Hz Operation 1 8 select Fan Inlet Bell 32 0268 Match With Blower Wheel P N 32 0313 1 32 0301 Match With Blower Wheel P N 32 0300 1 9 select Bushing Split Taper 31 0261 0 875 Dia 1 31 0275 24mm Dia 10 39 0255 Lower Hinge 1 set 11 39 0256 Upper Hinge 1 set 12 39 0291 Filter Mounting Knobs 2 13 10 9203 2 Exhaust Cover Plate 1 14 n a Fan Motor Mounting Plate 1 15 1...

Страница 42: ...Motor Shaft 50 Hz Operation 1 8 select Fan Inlet Bell 32 0301 Match With Blower Wheel P N 32 0300 1 32 0309 Match With Blower Wheel P N 32 0308 1 9 select Bushing Split Taper 31 0276 1 375 Dia 1 n a 38mm Dia Supplied With Blower Wheel 10 39 0255 Lower Hinge 1 set 11 39 0256 Upper Hinge 1 set 12 39 0291 Filter Mounting Knobs 2 13 10 9203 1 Exhaust Cover Plate 1 14 n a Fan Motor Mounting Plate 1 15 ...

Страница 43: ...38 United Air Specialists Inc Revised 9 02 Porta Hog Supra Conic Cartridge Dust Collector NOTES ...

Страница 44: ... ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT As Purchaser s exclusive remedy for any defects in the equipment UAS will exchange or repair any defective parts during the warranty period provided such parts are returned prepaid to UAS factory The obligation of UAS is limited to furnishing r...

Отзывы: