Operating Manual
© Dürr Systems GmbH
EcoGun AA MAN 2 P
Chyba! Pomocí karty Domů použijte u textu, který se má zde
zobrazit, styl Überschrift 1.
Version: 01
as of: 09/2014
12 / 46
2.6
Cleaning
- Uncouple the device from the pneumatic inlet and relieve the
pressure.
- Ensure that the ambient temperature is at lea
st 5°C below the flash
point of the used cleaning agents.
- Only use moistened cloths and paintbrushes to clean. Never use
any hard objects and never spray on cleaning agents with a gun.
Attention: In closed tanks, an explosive gas-air-mixture may
form. Therefore, never spray into a closed tank when cleaning
the device with solvent.
2.7
Handling of Liquids, Paints and Enamels
When preparing and processing paints and when cleaning the device,
observe all processing rules by the manufacturers of the used paints,
solvents and cleaning agents.
When painting and preparing and cleaning, wear the stipulated
protection outfit:
- goggles
- protective clothes
- protective gloves
- skin protection cream where appropriate
- respirator
Operate the device in a spray booth or at a spray wall with ventilation
turned on (suction) to ensure sufficient health and environmental
protection.
Wear corresponding protective clothing when processing hot materials
(max. 60°C).
Pos: 7 /CCP/Übergreife nde Kapitel/ 03 Tra nspo rt und La gerung @ 25\mod_1367920538954_20.do cx @ 358417 @ 12 @ 1