Operating Manual
© Dürr Systems GmbH
EcoGun AA MAN 2 P
Chyba! Pomocí karty Domů použijte u textu, který se má zde
zobrazit, styl Überschrift 1.
Version: 01
as of: 09/2014
30 / 46
7.3.3
Replacement of valve
Dismantle lever according to point 7.3.2.
Turn out valve packing gland 1134-4 to the front.
Pull out valve packing gland seal 1133-42 to the
front.
Insert new valve packing gland seal 1133-42.
Mount the parts vice versa.
7.3.4
Replacement of spray tip 001248-U8
Adjust the pump pressure at
0
bar, release
trigger 1248-U4
completely - pressure of hose
relieves.
Secure spray gun by a 90 ° clockwise rotation of
the safety lever 1237-3
Remove the lock nut 1248-4 by hand.
Take off nozzle set 1248-U2 to the front side.
Push out nozzle carrier from nozzle set
backwards.
Deposit nozzle carrier complete in cleaning fluid
respectively install another nozzle carrier complete
according to these
steps vice versa. (Cleaning
needle for nozzle order-
number 00345-44)
o
Replace if necessary, seal 1240-58.
Assembly in reverse order
Pos: 19 /CCP/Übergre ifende Kapitel/09 Entso rgung @ 29\mod_1384179559462_20.docx @ 397616 @ 1 @ 1
7.3.5
Replacement of gasket
Adjust the pump pressure at
0
bar, release
trigger 1248-U4 completely - pressure of hose
relieves.
Secure spray gun by a 90 ° clockwise rotation of
the safety lever 1237-3.
Remove the lock nut 1248-4 by hand.
Take off nozzle set 1248-U2 to the front side.