9.5 Setting the pressure reducer
The compressed air connection to the pressure
reducer has a constant pressure of 1 bar (set at
the factory).
10
8
9
5
5 Pressure reducer
8 Quick-release coupling
9 On/Off switch
10 Pressure gauge
The pressure reducer (5) regulates the desired
working pressure at the quick-release coupling
(8).
The pressure reducer (5) can be adjusted. The
maximum constant operating pressure is 5 bar.
Adjusting the pressure reducer:
The constant operating pressure can be adjust-
ed by turning the pressure reducer (5). The
pressure can be read off at the pressure gauge
(10).
i
To increase the supply pressure:
Turn the
pressure reducer (5) clockwise towards "+".
i
To decrease the supply pressure:
Turn the
pressure reducer (5) anti-clockwise towards
"-".
EN