Changing / Inspecting the Carbon Brushes
The carbon brushes in conjunction with the AVR regulates
power from the generator. The carbon brushes are wearable
parts and should be inspected every 250 running hours.
Remove generator cover
Remove bolt from brush
Disconnect AVR wires
Remove the 2 bolts of the generator cover then pull the cover
off the generator.
Remove the bolt holding the carbon brush.
Remove the two wires from the AVR on the carbon brush
1.
2.
3.
69
Содержание XP13000HXT
Страница 2: ......
Страница 5: ......
Страница 20: ...20 ...
Страница 44: ...44 ...
Страница 51: ...51 ...
Страница 55: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 55 ...
Страница 67: ...TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator 67 ...
Страница 73: ...Replace generator cover Replace the back cover of the generator and secure it with the 2 bolts 8 73 ...
Страница 74: ...WIRING DIAGRAM 74 ...
Страница 75: ...75 ...
Страница 81: ......
Страница 82: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX REV XP13000HXT 09102021 ...