Programming
Service Instructions 667 PREMIUM - 03.0 - 01/2018
91
Fig. 57: Example
ParameterView
active
When
ParameterView
is active, the item
ParameterCall
is added to
the menus in both Manual mode and Automatic mode. This function is
described separately (
14.7.3 Setting the Input configuration (
Input Config
) parameter
Configure and allocate the inputs here. The table shows the inputs and
their allocation.
Machine input signal
Input
Bu
tt
on
s on
t
h
e
bu
tt
on
b
a
r
S1
X120T.3
S2
X120T.16
S3
X120T.4
S4
X120T.17
S5
X120T.5
S6
X120T.18
Knee button S1
X120T.15
Knee button S2
X120T.2
Electronic handwheel S1
X100B.15
Operation lock input
(input on the circuit board)
X120B.2
DB3000 IN (X23)
(input on the circuit board)
X120B.15
Light barrier (X21) (optional)
X100B.4
Additional button S1 (optional)
X120B.16
Additional button S2 (optional)
X120B.4
On/Off.........
Start Trim° 125
Stop Trim° 20
°
Speed 150
T0203
T0200
T0210
T0211
Содержание 667 PREMIUM
Страница 1: ...667 PREMIUM Service Instructions...
Страница 10: ...About these instructions 8 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 28: ...Working basis 26 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 70: ...Thread cutter 68 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 98: ...Programming 96 Service Instructions 667 PREMIUM 03 0 01 2018 Fig 62 Connecting adapter to DACcomfort...
Страница 120: ...Programming 118 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 130: ...Maintenance 128 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 132: ...Decommissioning 130 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 134: ...Disposal 132 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 146: ...Troubleshooting 144 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 149: ......