Software settings
Additional Instructions M-TYPE DELTA - 00.0 - 08/2019
21
4 Software settings
To activate the remaining thread monitor in the software:
1. Log in as a technician (
Operating Instructions
).
User: technician
Password: 25483
2. Open the menu
Navigation >
Settings >
Machine Configuration
and press the
Input/Output
Configuration
button.
3. Press the
Configuration of the outputs
button.
4. Check in the section
OUT06(A2.X22.02)
if the value is set to
2
.
5. Open the menu
Machine Configuration
and press the
RFW/SSD
button.
6. Turn on the checkbox in the
t 06 00
parameter.
7. Set each of the following parameters to the value
1.7
:
•
t 06 02
(RFW limit, right side)
•
t 06 03
(RFW intensity, right side)
•
t 06 04
(RFW limit, left side)
•
t 06 05
(RFW intensity, left side)
8. Press the
Navigation
button.
The control panel shows a prompt to restart the machine.
9. Switch off the machine.
10. Switch on the machine again.
11. Open the menu
P > Main Parameters
and press on the text next
to the parameter
O 06 00
Bobbin monitor mode
.
12. Set the value to
Monitor
.
The remaining thread monitor is activated.