33
en
Problem
Potential cause
Solution
Sec-
tion
Flushing duration is too
short
Flushing duration is incor-
rectly set
>
Increase the flushing
duration
6.4
Flushing duration is too
long
Flushing duration is incor-
rectly set
>
Reduce the flushing
duration
6.4
11. Technical data
The identification plate is on the back page of the hygiene flush. This product conforms
to all the appropriate EU guidelines.
11.1 Hygienic flush for mains operation
Article number
WD6002 000 000
Rated voltage
100-240 VAC/ 6 V DC
Frequency
50-60 Hz
Nom. power consumption
max. 6 W
11.2 Hygienic flush for battery operation
Article number
WD6003 000 000
Rated voltage
6 V
Nom. power consumption
max. 6 W
Battery
CR-P2 lithium battery
Warranty
Our warranty terms can be found in our
General Terms and Conditions (GTC) at
www.pro.duravit.com