Setting the flush duration per flush (F1)/flush packages per hygiene flush (F3)/
interval time (F4)
You can set the flush duration per flush (F1), the number of flush packages per hygiene
flush (F3) and the interval time (F4).
> Press and hold the F1 button (flush duration per flush), the F3 button (flush packages
per hygiene flush) or the F4 button (interval time) and press “+” or “-”.
The settings are increased/decreased by the corresponding steps (see table 1: Hygiene
flush).
The status LED flashes. The changes are saved.
Retrieve the current settings (see 6.3 Retrieving settings) to check that your settings
have been saved.
Setting the starting time delay (F2 + F4)
The starting time for the hygiene flush is set the first time you activate it. You can
adjust the starting time delay of the hygiene flush in 4-hour steps.
> Press the F2 and F4 buttons once simultaneously and then press “+”.
The starting time delay is delayed by the corresponding steps.
> Press the F2 and F4 buttons once simultaneously and then press “-”.
The starting time delay is brought forward by the corresponding steps. The status LED
flashes according to the steps that are set every time after you press the buttons (see
table 1: Hygiene flush) and then lights up constantly for approx. 5 sec. The changes
are saved.
The starting time for the hygiene flush is set the first time you activate it and a
hygiene flush occurs. For example, if you activated the hygiene flush at 6:00 pm, it will
always subsequently be triggered at 6:00 pm.