8
penetrates into the attic. Figure 4 shows a
typical 2-story installation with an attic. Note:
a Firestop is not installed where the chimney
penetrates through the roof. The Firestop is
installed on the underside of the ceiling/floor
framing (Fig. 5). Use a minimum of either (1)
8 penny nail or (1) 1-1/4” wood screws per
corner.
8. Assemble Chimney Sections: Chimney
sections are connected by lowering the female
end of a Chimney Section onto the male end
of a previous section of chimney. Sheet metal
screws are required to connect Chimney
Section together. For each additional Chimney
Section use (4) Sheet metal screws provided,
to make a secure connection between the
chimney sections (Fig. 6). Do not penetrate
the inner liner of the chimney. Use a Wall Strap
every eight (8) feet of chimney height.
9. Supplementary Support and Stabilizer:
Install a Supplementary Support if total
chimney height is greater than 50-feet, or
if the fireplace manufacturer requires it. If
additional support is needed, install one or
more Supplementary Supports which can each
support 25-feet of chimney (Fig. 7). Clamp the
Supplementary Support band around the pipe
using the nut and bolt provided, and anchor
the support to nearby building framing. Always
FRAMING
Figure 5
Figure 6
Figure 7
SECURE BRACKET TO FRAME
SUPPORT UP TO
25 FEET OF CHIMNEY
MAINTAIN 2" CLEARANCE
EACH SUPPLEMENTARY
INSTALL SUPP. SUPPORT
IF HEIGHT EXCEEDS 50’
OR IF REQUIRED BY THE
FIREPLACE MANUFACTURE
FROM CHIMNEY TO FRAMING