Display

3½ LCD screen

Super range indication

LCD display screen will display “OL”

Low battery indication

      will be displayed on the screen

Input polarity indication

Automatically displays “-”

Power supply

2 x 1.5V AAA batteries

Dimensions

225mm x 38mm x 26mm

 

ACCURACY SPECIFICATIONS

• 

The accuracy is applicable within one year of calibration.

• 

Reference conditions: the environmental temperature is 18°C to 28°C and relative 

humidity is no more than 80%.

DC Voltage

Range

Resolution

Accuracy

200mV

0.1mV

± (0.5% r 3)

2V

0.001V

20V

0.01V

200V

0.1V

600V

1V

± (0.8% r 5)

• 

Input impedance: 

10MΩ.

• 

Maximum input 

voltage: DC or AC 

600V RMS.

AC Voltage

Range

Resolution

Accuracy

2V

0.001V

± (0.8% r 3)

20V

0.01V

200V

0.1V

600V

1V

± (1.0% r 5)

• 

Input impedance: 

10MΩ.

• 

Maximum input 

voltage: DC or AC 

600V RMS.

• 

Frequency range: 

40Hz~400Hz

DC Current

Range

Resolution

Accuracy

20mA

0.01mA

± (1.8% r 5)

200mA

0.1mA

• 

Input protection: 

FF250mA/600V fuse.

AC Current

Range

Resolution

Accuracy

20mA

0.01mA

± (2.0% r 5)

200mA

0.1mA

• 

Input protection: 

FF250mA/600V fuse.

Содержание D03127

Страница 1: ...1 MODEL D03127 Digital Multimeter Pen Type...

Страница 2: ...rview 4 Measurement Operation 5 AC DC Voltage Measurement 5 AC DC Current Measurement 5 Resistance Measurement 6 Diode Measurement 6 Connectivity Test 6 Non contact Voltage Detection 6 General Technic...

Страница 3: ...instrument around explosive gas steam or in a wet environment When measuring connect the zero ground line first then connect the live wire When disconnecting ensure you disconnect the live wire first...

Страница 4: ...unit is turned the default mode is automatic range on or the function is switched the instrument displays AUTO symbol The operations of entering or quitting manual range are as follows In automatic r...

Страница 5: ...screen When measuring DC current the display also shows the voltage polarity of the red probe test point Note If OL is displayed it means that the instrument exceeds the measurement range of the instr...

Страница 6: ...50 the buzzer will sound Warning Firstly disconnect the power supply of the circuit to be measured and fully discharge all high voltage capacitors After completing all measurements always disconnect t...

Страница 7: ...humidity is no more than 80 DC Voltage Range Resolution Accuracy 200mV 0 1mV 0 5 reading 3 2V 0 001V 20V 0 01V 200V 0 1V 600V 1V 0 8 reading 5 Input impedance 10M Maximum input voltage DC or AC 600V...

Страница 8: ...ore than about 50 Testing current about 1mA open circuit voltage about 2 8V Input protection Maximum DC or AC 600V RMS REPLACING THE BATTERIES Turn off the power supply and disconnect the probe from t...