6
DIODE MEASUREMENT
•
Move the rotary dial to the position and switch to the diode function.
•
Contact the red probe to the anode of the measured diode, and the black probe to
the cathode of the measured diode.
•
The reading on the screen is the approximate value of the diode forward voltage
drop. If it is connected in reverse, it will display “OL”.
Warning
•
Firstly, disconnect the power supply of the circuit and discharge all high voltage
capacitors.
•
If the diode to be tested is an open circuit or with reverse polarity, the instrument
will display “OL”.
•
After completing all measurements, always disconnect the probe and the
measured circuit.
CONNECTIVITY TEST
•
Move the rotary dial to the position, press “FUNC.” and switch to the
connectivity function.
•
Contact the probe to both ends of the measured circuit. When the resistance of the
measured circuit is below 50Ω, the buzzer will sound.
Warning
•
Firstly, disconnect the power supply of the circuit to be measured and fully
discharge all high voltage capacitors.
•
After completing all measurements, always disconnect the probe and the
measured circuit.
NON-CONTACT VOLTAGE DETECTION
•
Move the rotary knob of the instrument to NCV.
•
Approach the non-contact voltage induction area of the instrument to the live wire
of the AC voltage (less than 5mm).
•
The non-contact voltage indicating light of the instrument will light up. At the same
time there is a ‘beep’, which indicates that there is AC voltage on the fire wire.
GENERAL TECHNICAL SPECIFICATION
Environmental conditions
for use
IEC/EN 61010-1 600V CAT III, pollution level 2, altitude
<2000m
Working environment
temperature & humidity
0~40°C
Storage environment
temperature & humidity
-10~60°C (remove the battery when it is below 70%RH)
Temperature coefficient
0.1 x accuracy/°C
Max. Voltage allowed
between measuring
terminal and ground
DC or AC 600V RMS
Fuse Protection
Fuse FF 250mA/600V
Sampling rate
About 3 times/second
Содержание D03127
Страница 1: ...1 MODEL D03127 Digital Multimeter Pen Type...