5
•
Overload protection: 200mV range: 250V DC or RMS;
•
The rest ranges: 600V DC or RMS.
Direct Current Measurement
Range
Resolution
Accuracy
20μA
0.01μA
±1% of reading, ±3 digits
200μA
0.1μA
±1% of reading, ±3 digits
2mA
1μA
±1% of reading, ±3 digits
20mA
10μA
±1% of reading, ±5 digits
200mA
100μA
±1.5% of reading, ±5 digits
10A
10mA
±3% of reading, ±10 digits
•
Overload protection: F1 200mA/250V Fuse F2 10A/250V
*MAS838, no 20μA position
Alternating Voltage Measurement
Range
Resolution
Accuracy
200V
100mV
±1.2% of reading, ±10 digits
600V
1V
±1.2% of reading, ±10 digits
•
Overload protection: 600V DC or RMS
•
Frequency range: 40Hz to 400Hz
•
Display: Average (effective value of sinusoid)
Resistor
Range
Resolution
Accuracy
200
Ω
0.1
Ω
±0.8% of reading, ±5 digits
2k
Ω
1
Ω
±0.8% of reading, ±2 digits
20k
Ω
10
Ω
±0.8% of reading, ±2 digits
200k
Ω
100
Ω
±0.8% of reading, ±2 digits
2M
Ω
1k
Ω
±1.0% of reading, ±5 digits
•
Maximum open circuit voltage: 3.2V
•
Overload protection: 250V DC or RMS
20V
10mV
±0.5% of reading, ±3 digits
200V
100mV
±0.5% of reading, ±3 digits
600V
1V
±0.8% of reading, ±5 digits
Содержание D03125