background image

2

IMPORTANT SAFETY INFORMATION
Please read these instructions carefully before use and retain for future 

reference.

Important safety information. Read the instructions carefully.
High voltage. Danger.
Ground.
Double Insulation (Class II safety equipment).

Fuse must be replaced as per the specification herein.

!

200mA/250V

•  When using electrical appliances basic safety precautions should always 

be followed.

•  The instrument can only be used in conjunction with the probe, for the 

compliance with safety standards. If the probe needs replacing due 

to damage, the replacement must be of the same type or of the same 

electrical specifications.

• 

Do not exceed the input limits specified for each range.

•  When the instrument is measuring, do not touch the input terminal not in 

use.

•  When a measurement range is uncertain, turn the function/range switch to 

the maximum range position.

•  Before turning the function/range switch, make sure the probe is open with 

the circuit being measured.

•  Before on-line resistance measurement of voltage higher than 60V 

DC/30V AC, remember to keep your fingers behind the hand shield of the 

probe.

•  When measuring a TV set or switch power supply, watch for pulse in the 

circuit that may damage the multimeter.

•  Before measuring any transistor, make sure the probe is not connected to 

any circuit being measured.

•  Before taking the measurement of voltage with the probe, make sure there 

is no electronic element connected to the test socket of the transistor.

•  One Instruction manual

•  One pair of probes

•  One package

•  One 9V battery NEDA 1604 6F22

•  One K Thermocouple sensor (MAS838 only)

•  Rubber case (optional extra)

WHAT’S INCLUDED

Содержание D03125

Страница 1: ...1 3 DIGITAL MULTIMETER MODEL D03125 ...

Страница 2: ...suring do not touch the input terminal not in use When a measurement range is uncertain turn the function range switch to the maximum range position Before turning the function range switch make sure the probe is open with the circuit being measured Before on line resistance measurement of voltage higher than 60V DC 30V AC remember to keep your fingers behind the hand shield of the probe When meas...

Страница 3: ...gital multimeter features stable high reliable and anti drop performance It is provided with an LCD display 15mm in height designed for clear reading The circuit design takes LSI double integral A D converter as its core under the protection of an overload protection circuit making it a superior and handy instrument It can be used to measure DC and AC voltage DC current resistance diodes transisto...

Страница 4: ...lay Appearance dimension 138mm x 69mm x 31mm Weight 170g Direct Current Voltage Measurement Range Resolution Accuracy 200mV 100μV 0 5 of reading 3 digits 2V 1mV 0 5 of reading 3 digits Display 3 digital 15mm height 7 sections LCD display Backlight Press the BACKLIGHT button to turn on the backlights which will last for five seconds To turn it on again press the button when required Function and Ra...

Страница 5: ...n Alternating Voltage Measurement Range Resolution Accuracy 200V 100mV 1 2 of reading 10 digits 600V 1V 1 2 of reading 10 digits Overload protection 600V DC or RMS Frequency range 40Hz to 400Hz Display Average effective value of sinusoid Resistor Range Resolution Accuracy 200Ω 0 1Ω 0 8 of reading 5 digits 2kΩ 1Ω 0 8 of reading 2 digits 20kΩ 10Ω 0 8 of reading 2 digits 200kΩ 100Ω 0 8 of reading 2 d...

Страница 6: ...itch to the range of V and connect the probe to the power supply or load to be measured The polarity touched by the red probe will be on the display Plug the instrument in and check the 9V battery If it is low the symbol will display meaning the battery needs replacing The besides the probe jack indicates that the input voltage or current should not exceed the specified limits in orderto protect t...

Страница 7: ...rent will blow the fuse Alternating Voltage Measurement Place the red probe into the VΩmA jack and the black one into the COM jack Turn the switch to V and connect the probe to the power supply or load to be measured Resistance Measurement Place the black probe into the COM jack and the red one into the V Ω Hz jack Turn the switch to the COM jack and connect the probe to the resistor being measure...

Страница 8: ...ints is less than 100Ω the built in buzzer will sound to indicate the continuity between the two points Temperature Measurement Turn the switch to the C position and insert the black probe of the thermocouple sensor into the COM jack and the red into the V Ω mA jack Place the operating terminals temperature measurement terminals onto or inside the object being measured and directly read the temper...

Отзывы: