3-10
Chapter 3 Advanced Operation
Irreg Set
01
P Length 297.0
Fold1 0.0
Fold2 0.0
7
Press the
key.
Inputted numerical value is set, and [Fold1]
can be changed.
8
Input [Fold1] using the numerical
keypad.
Input [850].
Irreg Set
01
P Length 297.0
Fold1 85.0
Fold2 0.0
9
Press the
key.
Inputted numerical value is set, and [Fold2]
can be changed.
10
Input [Fold2] using the numerical
keypad.
Input [950].
Irreg Set
01
P Length 297.0
Fold1 85.0
Fold2 95.0
11
Press the
key.
The inputted numerical value is set, and the
display will return to the top screen.
The procedures taken after that will be the same as the
Chapter 2 “3. Standard Folding of Standard Paper”
(p.2-5)
The value of air volume of each fan, paper ejection conveyance amount, and stacker roller position that are
changed during special folding will be registered automatically.
When the registered numerical value has been fine-adjusted
• Press and hold the
key to register the numerical value after fine-adjusting the registered value using
the stopper adjustment key. The buzzer sounds “pii” and the numerical value that has been fine-adjusted
is registered.
• When turning off the power without registering the value, the fine-adjusted numerical value will be
cleared.
• Air volume of each fan, paper ejection conveyance amount, and stacker roller position that are changed
during special folding will be registered automatically.
3-2. Using the registered data
Press the custom folding key to select the