![Dupla Twin-Control Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/dupla/twin-control/twin-control_using-instruction_2540154030.webp)
30
9. Technical specifications
Operating voltage:
230 V, 50 Hz
Connected load for each slot:
Max . 2,000 W (ohmic load)
Total connected load of the connection strip:
Max . 3,000 W (ohmic load)
Connecting cable length:
1 .5 m
Cable control unit - control strip length:
2 m
pH control range:
4 .0 – 9 .9
pH display range:
4 .0 – 9 .9
pH control accuracy:
+/- 0 .1 (reference value)
pH switch hystereris:
0 .1
(the difference between the on and off switching point)
pH alarm window:
0 .1 – 4 .0
pH calibration memory:
Six-week
BNC Adaptor cable length:
20 cm
Temperature display range:
-9 .9 – 99 .9 °C
Temperature control range:
10 .0 – 40 .0 °C
Temperature alarm range:
0 .1 – 10 °C (00 means ‘no alarm’)
Temperature display accuracy:
0 .1 °C
Temperature control accuracy:
0 .1 °C
Temperature sensor tolerance:
+/- 0 .5 °C (calibratable)
Temperature sensor calibration range:
+/- 5 .0 °C
Sensor cable length:
3 m
Timer
mode (automatic) switching:
Max . 8 On-/Off
Timer
mode (interval) switching on time:
Minimum 1 sec . / maximum 23 hrs ., 59 min . and 59 sec .
Timer
mode (interval) switching off time:
Minimum 30 min . / maximum 96 hrs . and 59 Min .
10. EC declaration of conformity
The manufacturer declares that the devices comply with the requirements of the relevant EMC and LVD standards and
therefore conform with EC directives 2004/108/EC and 2006/95/EC .