![Dupla Twin-Control Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/dupla/twin-control/twin-control_using-instruction_2540154016.webp)
16
5.3 pH programming
Please note:
pH control is an alternative programming process to temperature 1 for slot 1.
Entering the programming mode,
pH
is displayed and
SET
flashes .
If you want to programme the pH Set point, press
. Proceed making your settings with item 5 .3 .1 of the instruc-
tions .
If you want to activate the night off function press another time the
▼
, button until
flashes and confirm by
pressing the
button . Continue making your settings with item 5 .3 .2 of this instructions .
If you want to programme the pH alarm, press the
▼
button again until the alarm clock flashes and confirm by pres-
sing the
button . Proceed making your settings with item 5 .3 .3 of the instructions .
If you want to calibrate your pH-Electrode, press the
▼
button to select
CAL
and confirm by pressing the
button . Proceed making your settings with item 5 .3 .5 of the instructions .
5.3.1 pH set point programming
When or your last set value and
pH
are flashing, press the
button to set the pH point .
When
flashes, press the
button to confirm .
or your last programmed value will flash .
Please note:
The pH Set Point presetting is . Depending on water values where your fish come from, higher
or lower values could be required.
When or your last set value flashes,use the
▲
or
▼
button to set the desired pH value between and , and
acknowledge with
.
When the pH Set Point Programming is finished,
is flashing .