21
Basic Calibration Procedure (Continued)
Hectaremeter Settings (Continued)
Example 1 :
Computronics 1100 Area Meter Setup for 15 Run Linkage Renovator
(Referring to Sowing Width Table Page 20)
15 Run Machine x 150mm Spacings = 2.25m Sowing Width
Drive Ratio From Wheel to Sensor = 0.4658
Rolling Circumference of Tyre = 1.278m
(Refer Page 16)
H1
- Distance per Pulse =
Circumference of Tyre
Drive Ratio
=
1.278
0.4658
= 2.743m
Therefore:
H1 Setting
=
2743mm
Distance Travelled per Pulse
and
H2 Setting
=
2.25metres
Effective Sowing Width
Please record here the settings for your machine in case you
are required to re-enter them at some time in the future.
It is advisable as with all things electronic to have a backup of
your totals. We suggest you record these on a daily basis in a notebook or diary.
H2
H1
Pt. No. 67376
Issue 0207