www.factorybuysdirect.com
200376-01A
20
Ignitor Button
Control Knob
Figure 20 - Ignitor Button and Control
Knob Locations (Logs will vary from
those shown)
8. Turn control knob counterclockwise
to the desired heating level. The main
burner should light. Set control knob to
any heat level between 1 (LO) and 5 (HI).
Note: Please wait one minute after shut-
ting off heater to allow the control valve
to reset before starting again.
OPERATION
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
WARNING: If input gas
type is NG, make sure NG pilot
burner ignites. If input gas type
is LP, make sure LP pilot burner
ignites.
Shutting Off Heater
Turn control knob clockwise
to the
OFF position.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise
to the
PILOT position.
TO TURN OFF GAS TO APPLIANCE
Figure 21 - Pilot
(Back of pilot
shown for clarity)
Pilot Air
Inlet Hole
Natural Gas
Burner
Propane/LP
Gas Burner
Thermocouple
Pilot Air Inlet Hole
Ignitor
Electrode
1. Follow steps 1 through 7 under
Lighting
Instructions
, page 19.
2. With control knob in PILOT position, strike
match, and hold near pilot. Press in control
knob; pilot should light.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
4. Make sure the fireplace screen is in place
before operating heater.
MANUAL LIGHTING PROCEDURE
THERMOSTATIC CONTROL OPERATION
The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses the
room temperature. At times the room may ex-
ceed the set temperature. If so, the burner will
shut off. The burner will cycle back on when
room temperature drops below the set tem-
perature. The control knob can be set to any
comfort level between HIGH (5) and LOW (1).
Note: The thermostat sensing bulb measures
the temperature depending on housing con-
struction.