12. Solar Module Connections
Please ensure that the solar modules are connected in parallel as per the diagram below.
Incorrect connection of the solar array could cause permanent damage to the refrigerator
and its components.
Only use the solar cable and solar connectors provided. Follow good electrical installation
practices when installing the cables:
Route the cables where they cannot be
damaged or subjected to excessive heat.
Do not install the cable around tight bends.
Ensure that the cable is supported along the full
length of its route to the refrigerator, using the
cable ties and bases supplied.
Use the supplied length of conduit to protect the solar
array cables as they enter the building or as it passes
over sharp edges. The conduit is slit so that it can be
easily clipped over both cables. Once on, cable tie it in
place and if necessary fill the external end with the
supplied silicon sealant to seal the hole.