9
Installation and Operation of:
FlexBake 5™ Integrated Ventilation System
Step 6
Carefully set the IVS assembly on top of the oven
aligning the IVS duct with the oven Exhaust Duct
flanges.
NOTE: Make sure the gasket from a.
remains properly in place.
Step 7
Install 4 screws (#10-24) to secure the IVS duct to
the oven exhaust duct.
Step 8
Install the 6 screws (3 per side)(Tek screws
previously removed in Step 7.)
Step 9
Connect the IVS assembly blower motor to the
oven harness.
IVS Blower
Motor
The IVS blower motor MUST be connected with
the proper voltage lead wire. On the IVS blower
motor, WHITE is Common, BLACK is the 208VAC
lead wire and RED is the 230VAC lead wire.
CAUTION
Step 10
Connect the IVS blower motor to the proper
voltage wire.
See wire diagrams on page 5