10
Installation and Operation of:
FlexBake 5™ Integrated Ventilation System
Step 11
Place the IVS blower adaptor gasket on to the
adaptor outlet, as shown.
IVS Blower
Adaptor Gasket
Step 12
Locate the IVS Cover and Exhaust Ring in position,
as shown. Do not install screws at this time.
Step 13
Locate the Exhaust Ring and position, as shown
and install the 4 screws (#8-32).
NOTE: Make sure the adaptor gasket
is properly in place.
Step 14
Align the IVS Cover holes and install the 14 screws
(#8-32) to secure it.
Step 15
Connect the IVS blower outlet as required per local
codes and/or other applicable codes using 5” rigid
metal duct work. Do not use plastic dryer duct
vent. Duct and clamps are not included with the
IVS.
Step 16
Verify Proper Connection of Proof and Bake oven to
Building Structure
ELECTRICAL SHOCK HAZARD.
THIS RESTRAINING DEVICE MUST ALWAYS
BE CONNECTED WHEN THE APPLIANCE
IS IN SERVICE. DISCONNECT ONLY FOR
SERVICING AND/OR CLEANING, THEN
RECONNECT WHEN THE APPLIANCE
HAS BEEN RETURNED TO ITS NORMAL
POSITION.