8. Other Functions
8.2 Projector Management using SNMP
The SNMP (Simple Network Management Protocol) enables to manage the
projector information, which is a failure or warning status, from the computer on
the network.
• It is recommended that SNMP functions are executed by a network
administrator.
• SNMP management software must be installed on the computer to monitor
the projector via SNMP.
NOTE
Standard MIB (MIB-2)
You can refer to the following items defined in system group of Standard MIB
(MIB-2).
Item
Description
sysName
Projector name is set.
sysLocation
The information on where it is located. It has character string
set in sysLocation (SNMP) in Projector Web Control - [Network
Settings] - [Common Setup].
sysContact
The information on the administrator's contact information. It
has character string set in sysContact (SNMP) in Projector
Web Control - [Network Settings] - [Common Setup].
Enhanced MIB
You can get configuration information by using Enhanced MIB for projectors.
Enhanced MIB for projectors can be downloaded from [Port Settings] page in
Projector Web Control.
Trap
When an error or warning occurs in the projector, a notification can be sent to the
specified address.
In addition to email alert shown in 8.1 Email Alerts (
89
), the following notification
can be sent.
Item
Description
Cold Start
When the projector is supplied with the power, it works as
below.
• If the STANDBY MODE is set to the QUICK START or
NORMAL: the projector's power status changes from “OFF” to
“Standby state”.
• If the STANDBY MODE is set to the NETWORK(WOL) or
SAVING: the projector's power status changes from “Standby
state” to “ON (light source is turned on)”.
(
SETUP menu in the Operating Guide).
Authentication Failure
The SNMP access is detected from the invalid SNMP
community.