ELECTRICAL CONNECTION
A qualifed electrician must carry out the electrical installation of this radiator. The electrical installation must comply with
the current UK regulations. Any claim on the warranty could be invalid if these requirements have not been met.
The radiator requires a 230/240V 50Hz power supply and is a double insulated product so does not require an earth
cable.
CONNECTING WIRES
L = Live
→
Brown
N = Neutral
→
Blue
FP = Pilot Wire
→
Black (if required for external programmer)
IF PILOT WIRE IS NOT REQUIRED INSULATE BLACK CABLE TO ENSURE IT DOES NOT COME INTO CONTACT
WITH ANY OTHERS WIRES OR TERMINALS.
The connecting wires must be of the appropriate section, in regards to the length of cable, type of cable and power rating
of the apparatus.
The apparatus must be connected into a connecting box.
We recommend that the connecting box is positioned 10cm to the right of the apparatus and at 15cm above the floor.
According to regulations, the apparatus must be connected to the power supply by means of an all-pole circuit breaker
with a contact gap of at least 3mm or by a thermal-magnetic circuit breaker.
LOCATION
The ideal place to site the Ducasa radiator is as close as possible to coolest wall in the room but it is not recommended to
site the radiator on un-insulated exterior walls, in this case, the part of the wall behind the radiator should be insulated.
In bathrooms, the radiators must not be sited inside the protected area. The control unit switches must not be reachable,
directly or indirectly, by a person in the bath or shower.
The radiator, under no circumstances, should be installed below an electric power point.
Choose the location of the radiator in respect of the minimum distances that are indicated below.
3. INSTALLATION INSTRUCTIONS
2. TECHNICAL DATA
MODEL
Vitro 750
Vitro 1200
Vitro 1600
Power (w)
750
1200
1600
Voltage
230V /1Ph /50Hz
Dimmensions
WxHxD
(mm.)
670x500x110
840x500x110
1000x500x110
CLASS
II
II
II
figure 2