![Ducasa Colorado DGi+ Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/ducasa/colorado-dgi/colorado-dgi_manual_2537513015.webp)
15
21
.5°C
Wed. 11:00
Set point:
COMFORT
21
.5°C
Wed. 11:00
Set point:
COMFORT
21
.5°C
Wed. 11:00
Set point:
COMFORT
Time
Runback ON, Setback ON,
Max Temp OFF
Runback
Set point
Temperature
Heating End
Heating Start
Setback Limit
Temperature
Temp Range available to User
Runback ON, Setback ON,
Max Temp ON
Temperature
Runback
Set point
Heating End
Time
Temp. increased
By user to Max.
Max Temp.
Set point
Heating Start
Setback Limit
Temperature
Temp Range available to User
When Runback and Setback are activated then
the user has a limited choice of temperature
between the Setback setting and the Runback
setting.
Outside of the Runback period the temperature
will fall to the Setback temperature if the towel rail
is not re-activated.
When all 3 settings are activated then the user
has a choice between Setback as a minimum and
the Max temp setting as a maximum.
The Towel rail will always come on at the
Runback set point.
In the example above the user has activated
Runback and then increased the temperature to
the Max Temp set point after a time.
ERROR CODES
The Towel rail continuously checks to ensure
that it is working correctly all the time, however
in some cases the towel rail may display an Error
code on the screen.
Below you will find each code and a short
description on the cause of each issue.
OC Disconnected or Open circuit temperature
sensor.
SC Damaged or Short circuit temperature
sensor.
TROUBLESHOOTING
If the power of the Lithium
battery drops, in the screen,
a small icon will remind the
user that the battery is flat.
When a towel rail has been
paired with a
Gateway, the text
“Link” and an antenna with
flashing waves appears on
the top right of the screen.
When the Gateway is
not powered or it is too far
away from towel rail, the
Link text alternates with a
red antenna without waves
to tell you that the towel rail
cannot communicate with
the Gateway..
If a towel rail is paired with a Gateway, and the
internet connection is lost the heating system is
not accessible from the
App.
However the programe remains in the towel rail
memory and continues with the last user setting
so long as the lithium battery is not flat.
The Lithium battery (CR2032) life is around 5
years from date of manufacture, this life can be
decreased depending storage conditions.
To change the battery contact your installer or
an electrician.