Ducasa Colorado DGi+ Скачать руководство пользователя страница 10

10

22

.5°C

1h 35m

BOOST

set temp

+

TIME

 

1h

BOOST

Set time:

OK

21

.5°C

Wed. 11:00

Set point:

COMFORT

Next Program ON Time

Starts at:Tue. 20:00

Set point:

21

.5°C

Wed. 11:00

Wednesday

COPY

07:00      12:00                   x 
17:00      20:00                   x     

ON    OFF  

mode     

  

PROGRAM

add period

Copy Wednesday to:

Mon

PROGRAM

Tue

Thu

Sat

Wed

Fri

Sun

OK

CANCEL

CONFIG

COMFORT
ECO
ANTI-FROST
PROGRAM
SETTINGS

COMFORT

COMFORT

21

.0°C

Set point:

OK

ECO

18

.0°C

Set point:

OK

ANTI-FROST

7

.0°C

Set point:

OK

 The first press of any button will wake up the towel rail any further 

button presses will activate the function required. 

Once  the  program  for  the 

day  is  complete,  it  can  be 

copied  to  other  days  in  the 

week by selecting COPY from 

the programming screen. To 

do this use the +/- button to 

select “COPY” and then 

Mode/OK

 to confirm.

The  copy  screen  will 

appear  and  the  day  that  is 

being copied from will not be 

available. (Wednesday in the 

example.)

Select  the  days  to  copy  using  +/-  button  to 

highlight  a  day  and  then 

Mode/OK

  to  select  it. 

Once  you  are  happy  with  the  selection  use  +/- 

button to highlight “OK” and press 

Mode/OK

The  screen  will  change  back  to  the  program 

menu.

To Exit press CONFIG and the screen will revert 

to  the  current  mode  of  operation  (MANUAL  or 

AUTO).

To  make  sure  your  program  is  running  Press 

the 

Mode/OK

 button until 

 is shown at the 

bottom of the screen.

The  screen  will  alternate  between  the  current 

programmed  temperature  mode  and  the  next 

programmed Comfort/Economy ON time. 

At any time, the temperature can be temporarily 

overridden  using  the  +/-  buttons.  At  the  next 

programmed mode change or midnight whichever 

is  soonest,  the  radiator  will  return  to  the 

programmed temperature

.

SET PROGRAM TEMPERATURES 

To adjust the temperatures used in AUTO mode, 

press  and  hold  the  CONFIG  button  until  the 

following screen appears:

Select either Comfort, Eco or Anti-Frost by using 

the  +/-  button  and  press 

Mode/OK

  to  enter  the 

adjustment setting.

Press the +/- button to change the temperature 

and then press Mode/OK to confirm and return to 

the CONFIG screen. Repeat the above process 

for the other program temperatures.

BOOST

The towel rail has a Boost mode that allows the 

user to temporarily override 

the current operating mode. 

The  Boost  button    will 

immediately turn on the towel 

rail for 1 hour at 2ºC warmer 

than room temperature.

To  adjust  the  BOOST  temperature,  use  the  +/- 

buttons.

To adjust the duration, press 

the  CONFIG  button,  the 

BOOST time  setting  screen 

will  be  displayed;  set  the 

required  time  between  1 

hour and 24 hours using the 

+/- buttons. To return to the 

BOOST screen press the CONFIG button.

You  can  quickly  adjust  the  duration  with  the 

BOOST  button  .  Each  press  will  increase  the 

duration of BOOST mode by 1h.

To  return  to  the  previous  mode  and  cancel  the 

Boost mode, press the 

Mode/OK

 button.

Содержание Colorado DGi+

Страница 1: ...E1400298 20220110 NOTE A qualified electrician must carry out the electrical installation of this towel rail The electrical installation must comply with current UK regulations Any claim on the warra...

Страница 2: ...P 7 Connecting to the smart command tevolve app 7 Geolocation 8 USING WITHOUT SMARTCOMMAND TEVOLVE APP 8 Using in operating modes 8 Setting the time and date 9 Entering a program 9 Set program tempera...

Страница 3: ...young children it is recommended to install this towel heater so that the lowest heating bar is at least 600 mm above the floor This appliance must only be installed according to this installation man...

Страница 4: ...QR code to access to the download It is also possible to programme each towel rail individually without theApp by using the built in controls and screen This may be convenient for single heaters howe...

Страница 5: ...tches and other control devices can be touched by a person in the bathtub or shower This product is rated as IP44 and can be located in zone 2 the area stretching 60cm outside the perimeter of the bat...

Страница 6: ...etween the 2nd and 3rd horizontal tubes from the bottom STEP 1 First the 4 supports are placed on the towel rail take a piece B fix the piece D with the screw C and insert it between two tubes from th...

Страница 7: ...u must first connect and register your Gateway To do this follow the instructions in the gateway manual Ensure you have downloaded and logged into the App using your user name and password then press...

Страница 8: ...nless it s turned back on again USING WITHOUT SMARTCOMMAND TEVOLVE APP USING IN OPERATING MODES To assist with the operation of the Colorado DGi the TFT screen is backlit and will stay illuminated for...

Страница 9: ...ting the time To exit the Date function press the CONFIG button To turn Daylight savings on or off select the DST function from within the time settings and then use the button to cycle the function O...

Страница 10: ...s shown at the bottom of the screen The screen will alternate between the current programmed temperature mode and the next programmed Comfort Economy ON time At any time the temperature can be tempora...

Страница 11: ...w a coloured bar across the bottom of the screen to encourage the user to set an economical temperature This feature is turned on and off in the ECO DISPLAY menu To de activate the beep when each key...

Страница 12: ...owel rail will restore normal function in any of these situations After 30 minutes If the temperature increases by 0 2 C for 1 minute from the point of activation Pressing any key on the Heater By def...

Страница 13: ...assword is turned off the Keylock Advanced Settings menu and Runback controls are accessible without entering a password The first press of any button will wake up the towel rail any further button pr...

Страница 14: ...os for each of the settings When Setback and Max temp is OFF the user has a choice between the minimum towel rail temperature of 7 C and the Runback temp setting Outside of the Runback period the temp...

Страница 15: ...rail continuously checks to ensure that it is working correctly all the time however in some cases the towel rail may display an Error code on the screen Below you will find each code and a short desc...

Страница 16: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Страница 17: ...elmax 0 0005 kW 0 0005 kW At minimum heat output elmin 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control pl...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...posed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types o...

Отзывы: