12
OFF
ON
Open Window
Wed. 11:00h
21
.5°C
Set point:
OFF
ON
Self Adaptive
OFF
ON
EASY mode
OFF (100%)
75%
50%
20%
LowSurfaceTemp
Wed. 11:00h
21
.5°C
Set point:
COMFORT
EASY
set temp
21
.5°C
Set point:
Wed. 11:00
LST 23%
Wed. 11:00h
21
.5°C
Set point:
PID
Hysteresis
.25°C
Hysteresis
.35°C
Hysteresis
.5°C
Hysteresis
.75°C
Control Type
Display temp
22.5°C
1.1°C
Temp. Offset
Celsius
Fahrenheit
UNITS
Use the +/- buttons to highlight the setting you
want to adjust and Mode/OK to enter.
The advanced settings are listed below:
.
The units menu allows the
main temperature units of
the towel rail to be chosen
between Celsius (°C) and
Fahrenheit (°F). Change
using +/- buttons and confirm
with
Mode/OK
.
This setting shows the
type of thermostat accuracy
currently being used. There
are 6 types of control. To
change the thermostat
accuracy use the +/- button
to highlight and confirm using the
Mode/OK
button.
This setting is used to
balance two radiators in
the same room or to sync
the Colorado DGi+ with a
thermostat.
The compensation can
be adjusted by +/- 3°C and is adjusted in 0.1°C
increments. Use +/- buttons to change the Offset
value, which will automatically be applied to the
Display temperature. Once you have applied your
Offset value press
Mode/OK
button to confirm.
In order to save energy, if a
window opens and causes a
sudden drop in temperature
the towel rail will stop heating.
If the towel rail is heating,
it will be disconnected for
30 minutes and shows the
Open Window icon on the
display.
The towel rail will restore
normal function in any of
these situations:
- After 30 minutes
- If the temperature increases by 0.2ºC for 1
minute from the point of activation.
- Pressing any key on the Heater
By default, open window detection is turned off.
Use +/- button to select ON or OFF and then press
Mode/OK
to save your change.
With this feature activated
the towel rail will learn
what time it should switch
on to achieve the required
room temperature at your
programmed time. The
towel rail will monitor the
room temperature over
a rolling 10 day period to
establish how quickly the
room reaches temperature
and uses this information
to switch the towel rail on at
the correct time.. To turn on/off use the +/- buttons
and confirm with
Mode/OK
.
The
Low
Surface
Temperature (LST) menu
will allow the output of the
heater to be limited to a
lower setting to prevent
the surface of the heater
becoming too hot.
It is recommended that if
the LST function is activated
then the towel rail should be
locked with a non-standard
password after activation to
prevent the function being turned off.
(See Password Section for details on changing
the factory default password).
To cycle between the different outputs use the
+/- buttons and confirm the selection with
Mode/
OK.
EASY Mode is a simple
mode of operation where
only the +/- buttons on
the towel rail operate to
increase or decrease the
temperature. The
Mode/OK
button is de-activated.
When running in Easy
mode the screen will show
EASY in the notification area
to let the user know that the
mode is active.
To exit EASY mode press
and hold the CONFIG button
for 10 seconds, then select
“off”, using the +/- button
and confirm by pressing
Mode/OK.