Ducasa Colorado DGi+ Скачать руководство пользователя страница 13

13

Status      ON

Change

Password

Runback Config

Setback

Max. Temp.

Runback

Confirm

OK  CANCEL

RESET

Status      ON

Change

Password

Status

ON

OFF 

Password

Status      ON

Change

Password

CONFIRM NEW

PASSWORD

 

  1 2 3 4  OK

ENTER

PASSWORD

        -  -  -  -   OK

Runback:  See  Runback 

Section on page 14

Password:  See  Password 

Section on page 14

Resetting  the  towel  rail 

will return all settings to the 

factory defaults and will also 

delete  any  ‘pairing’  with  a 

Gateway.

To activate the RESET feature select “OK” using 

the  +/-  buttons  and  then  press  the 

Mode/OK

 

button to confirm.

PASSWORD

The Password Function of the towel rail serves 

a number of functions; Keylock, Advanced menu 

access  and  also  Runback  access  when  the 

Runback is activated.  The Default password from 

the factory is four zero’s (0 0 0 0), however it is 

strongly recommended

 that once installation is 

complete that an alternative code is set. 

To  access  the  password  function  enter  the 

ADVANCED  SETTINGS  menu  (see  above)  and 

then select PASSWORD.

The  password  can  be  turned  on  or  off  and 

changed. 

To  turn  the  password  on  or  off,  select  Status 

using +/- buttons and press 

Mode/OK

.

Select  either  “ON”  or  “OFF”  using  +/-  buttons  

and press 

Mode/OK

.

If  you  are  reactivating  the  password  then  the 

Enter  New  password  screen  is  shown  (The 

password will always default back to 0 0 0 0).

If  the  password  is  turned  off,  the  Keylock, 

Advanced  Settings  menu  and  Runback  controls 

are accessible without entering a password.

 The first press of any button will wake up the towel rail any further 

button presses will activate the function required. 

To  Change  the  password  code  when  the 

password  is  active  select  Change  from  the 

password screen and using +/- buttons and press 

Mode/OK

.

Enter the new password using +/- buttons and 

Mode/OK

 to confirm the new number. Once “OK” 

is highlighted press 

Mode/OK

RUNBACK MODE

The towel rail comes with a Runback mode for 

use  when  the  heater  will  be  installed  in  areas 

where restricted user control is required.

When Runback Mode is active it allows the user 

to  set  the  towel  rail  to  run  for  a  specific  pre-set 

amount of time and temperature. It is also possible 

to set a maximum temperature (Max Temp) above 

the Runback setting to allow the user to increase 

the temperature within the limits allowed. 

After  the  Runback  time  period  ends  the  room 

temperature  will  return  to  off  (7°C)  until  the 

Runback is restarted.

 

It is also possible to set a minimum temperature 

to be maintained (Setback) outside of the Runback 

mode; when setback mode is activated the room 

temperature  will  only  fall  as  low  as  the  Setback 

temperature. The temperature will be maintained 

at this point until Runback is restarted.

NOTE:  Any  display  settings  will  be  used  in 

RUNBACK mode, eg. Backlight time and intensity, 

Eco mode etc. These should be adjusted prior to 

setting Runback to Active.

Содержание Colorado DGi+

Страница 1: ...E1400298 20220110 NOTE A qualified electrician must carry out the electrical installation of this towel rail The electrical installation must comply with current UK regulations Any claim on the warra...

Страница 2: ...P 7 Connecting to the smart command tevolve app 7 Geolocation 8 USING WITHOUT SMARTCOMMAND TEVOLVE APP 8 Using in operating modes 8 Setting the time and date 9 Entering a program 9 Set program tempera...

Страница 3: ...young children it is recommended to install this towel heater so that the lowest heating bar is at least 600 mm above the floor This appliance must only be installed according to this installation man...

Страница 4: ...QR code to access to the download It is also possible to programme each towel rail individually without theApp by using the built in controls and screen This may be convenient for single heaters howe...

Страница 5: ...tches and other control devices can be touched by a person in the bathtub or shower This product is rated as IP44 and can be located in zone 2 the area stretching 60cm outside the perimeter of the bat...

Страница 6: ...etween the 2nd and 3rd horizontal tubes from the bottom STEP 1 First the 4 supports are placed on the towel rail take a piece B fix the piece D with the screw C and insert it between two tubes from th...

Страница 7: ...u must first connect and register your Gateway To do this follow the instructions in the gateway manual Ensure you have downloaded and logged into the App using your user name and password then press...

Страница 8: ...nless it s turned back on again USING WITHOUT SMARTCOMMAND TEVOLVE APP USING IN OPERATING MODES To assist with the operation of the Colorado DGi the TFT screen is backlit and will stay illuminated for...

Страница 9: ...ting the time To exit the Date function press the CONFIG button To turn Daylight savings on or off select the DST function from within the time settings and then use the button to cycle the function O...

Страница 10: ...s shown at the bottom of the screen The screen will alternate between the current programmed temperature mode and the next programmed Comfort Economy ON time At any time the temperature can be tempora...

Страница 11: ...w a coloured bar across the bottom of the screen to encourage the user to set an economical temperature This feature is turned on and off in the ECO DISPLAY menu To de activate the beep when each key...

Страница 12: ...owel rail will restore normal function in any of these situations After 30 minutes If the temperature increases by 0 2 C for 1 minute from the point of activation Pressing any key on the Heater By def...

Страница 13: ...assword is turned off the Keylock Advanced Settings menu and Runback controls are accessible without entering a password The first press of any button will wake up the towel rail any further button pr...

Страница 14: ...os for each of the settings When Setback and Max temp is OFF the user has a choice between the minimum towel rail temperature of 7 C and the Runback temp setting Outside of the Runback period the temp...

Страница 15: ...rail continuously checks to ensure that it is working correctly all the time however in some cases the towel rail may display an Error code on the screen Below you will find each code and a short desc...

Страница 16: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Страница 17: ...elmax 0 0005 kW 0 0005 kW At minimum heat output elmin 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control pl...

Страница 18: ...18 NOTES...

Страница 19: ...19 NOTES...

Страница 20: ...posed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types o...