![Ducasa Colorado DGi+ Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/ducasa/colorado-dgi/colorado-dgi_manual_2537513013.webp)
13
Status ON
Change
Password
Runback Config
Setback
Max. Temp.
Runback
Confirm
OK CANCEL
RESET
Status ON
Change
Password
Status
ON
OFF
Password
Status ON
Change
Password
CONFIRM NEW
PASSWORD
1 2 3 4 OK
ENTER
PASSWORD
- - - - OK
Runback: See Runback
Section on page 14
Password: See Password
Section on page 14
Resetting the towel rail
will return all settings to the
factory defaults and will also
delete any ‘pairing’ with a
Gateway.
To activate the RESET feature select “OK” using
the +/- buttons and then press the
Mode/OK
button to confirm.
PASSWORD
The Password Function of the towel rail serves
a number of functions; Keylock, Advanced menu
access and also Runback access when the
Runback is activated. The Default password from
the factory is four zero’s (0 0 0 0), however it is
strongly recommended
that once installation is
complete that an alternative code is set.
To access the password function enter the
ADVANCED SETTINGS menu (see above) and
then select PASSWORD.
The password can be turned on or off and
changed.
To turn the password on or off, select Status
using +/- buttons and press
Mode/OK
.
Select either “ON” or “OFF” using +/- buttons
and press
Mode/OK
.
If you are reactivating the password then the
Enter New password screen is shown (The
password will always default back to 0 0 0 0).
If the password is turned off, the Keylock,
Advanced Settings menu and Runback controls
are accessible without entering a password.
The first press of any button will wake up the towel rail any further
button presses will activate the function required.
To Change the password code when the
password is active select Change from the
password screen and using +/- buttons and press
Mode/OK
.
Enter the new password using +/- buttons and
Mode/OK
to confirm the new number. Once “OK”
is highlighted press
Mode/OK
RUNBACK MODE
The towel rail comes with a Runback mode for
use when the heater will be installed in areas
where restricted user control is required.
When Runback Mode is active it allows the user
to set the towel rail to run for a specific pre-set
amount of time and temperature. It is also possible
to set a maximum temperature (Max Temp) above
the Runback setting to allow the user to increase
the temperature within the limits allowed.
After the Runback time period ends the room
temperature will return to off (7°C) until the
Runback is restarted.
It is also possible to set a minimum temperature
to be maintained (Setback) outside of the Runback
mode; when setback mode is activated the room
temperature will only fall as low as the Setback
temperature. The temperature will be maintained
at this point until Runback is restarted.
NOTE: Any display settings will be used in
RUNBACK mode, eg. Backlight time and intensity,
Eco mode etc. These should be adjusted prior to
setting Runback to Active.
Содержание Colorado DGi+
Страница 18: ...18 NOTES...