background image

08

09

U

N

PL

UG

 AFTER

U

SE

 - F

IRE R

ISK

DON’T FORGET 
TO 

REGISTER  

YOUR PRODUCT

WWW.DUALIT.COM/REGISTER

OR BY POST

1

2

2

Position the Steriliser on 

a flat surface away from 

sources of heat. Place the 

Steriliser as close to the 

wall socket as possible. 

Do not store or use 

the Steriliser in an 

appliance garage or 

under cupboards,

 

close to curtains or 

flammable material as 

the Steriliser will emit 

steam from the Steam 

Vents in the Lid. 

Do not cover vents, 

covering vents causes 

risk of fire.

Register your product at 

Dualit.com this will only take 

60 seconds; you will need 

the product model and 

serial number which is on 

the rating label on the base 

of the product.

Pour exactly 90ml of fresh tap water into the Water Recess. 

Do not exceed the max marker. You can use demineralised 

water if you want to reduce the number of times you need to 

descale.

3

Ensure that the Steriliser is 

placed on a heat resistant 

work surface. Do not 

operate on a tray. Do not 

let the cord hang over the 

edge of work surfaces or 

touch hot surfaces. 

SETTING UP

Read and follow these instructions before using your Steriliser. 

THIS IS AN ATTENDED APPLIANCE.

 Do not leave 

unattended during use, unplug after each use (risk of fire if an 

unattended appliance is left operating).

Never remove the Lid while the Steriliser is operating (Power Indicator Light is illuminated). 
This will cause a failure to sterilise. Please wait 5 minutes for the Steriliser to cool before 
removing the Lid. 

Warning: Hot water and steam may cause serious injury and 

burns; keep hands away from hot surfaces and steam vents. Risk of scalding.

Before first use, wash the Upper and Lower Racks and the Lid with warm soapy water and 

rinse thoroughly. Do not submerge the Base, Power Cord or Plug as there is a risk of electric 
shock and permanent damage to the appliance. 

U

N

PL

U

WH

EN NO

T IN

 U

SE

U

N

PL

U

WH

EN NO

T IN

 U

SE

3

Clean and rinse bottles, 

dummies and teats before 

sterilising. 

After filling your Steriliser with 90ml of water, 

place the Lower Rack into position. Ensure 

Lower Rack is positioned correctly with logo 

facing forward. 

Warning: The appliance 

will not sterilise if Lower Rack is 

incorrectly positioned.

USING YOUR STERILISER

Before first use or after a long period of no use, fill and then 

operate your Steriliser empty with no bottles on a Sterilise function          
(Steps 1-15 below).

It is important that all bottles, teats and accessories are empty, 
separated and that they are thoroughly cleaned using soap suds and rinsed in fresh water 
before placing in the Steriliser for sterilisation.

Warning: The Steriliser is only suitable for high temperature-resistant bottles 
and items that can withstand a temperature of 100°C.

1

4

Position baby bottles on the Lower Rack facing 

downwards with the necks over the locators. 

Place the bottle lids over the bases of the bottles. 

Notes: The Steriliser can accommodate a 

maximum of 6 bottles at a time. 

Warning: Only operate with 

90ml of water and do not over 

fill. Ensure water is not spilled 

or poured into the Air Vent 

area. Never use less than 90ml 

of water as sterilisation will 

not complete, risk of bacterial 

or viral contamination.

Tip - You can use a baby bottle 

as a measuring device or weigh 

90g of water.

Содержание baby 11040

Страница 1: ...Steam Steriliser Instruction Manual Guarantee DON T FORGET TO REGISTER YOUR PRODUCT WWW DUALIT COM REGISTER OR BY POST...

Страница 2: ...Unpack the box with care keeping all the packaging materials until you are satisfied everything is present and in working order Once satisfied remove any tags from the appliance body and recycle the...

Страница 3: ...gled in or tripping over a longer cord Do not allow cable to hang over the edge of a table or countertop Do not fill above the max mark on the water level indicator Risk of fire and electric shock Do...

Страница 4: ...will be sterile for 24 hours after cycle as long as the lid isn t removed FILTER HOLDER FILTER BASE FEET ICON FUNCTION DESCRIPTION Sterilise Only Sterilise up to 6 full bottles This function kills 99...

Страница 5: ...surfaces and steam vents Risk of scalding Before first use wash the Upper and Lower Racks and the Lid with warm soapy water and rinse thoroughly Do not submerge the Base Power Cord or Plug as there i...

Страница 6: ...uick Dry Without water this function will dry items that have been sterilised only and are still wet or dry any items that require a longer drying cycle 30 minutes FUNCTION DESCRIPTION TIME Sterilise...

Страница 7: ...ning in the Water Recess Note Pour water towards a front corner to ensure that no water goes into the Air Vent Risk of fire and electric shock If you wish to turn the Steriliser off during a sterilisa...

Страница 8: ...The Steriliser can be descaled by pouring just boiled water into the Water Recess up to the MAX marker then adding 30ml of Kilrock Espresso Coffee Machine Descaler This can be purchased on www dualit...

Страница 9: ...liser Element may have a build up of limescale This will show as white and or brown spots on the Steriliser Element and Water Recess 1 Descale your Steriliser regularly please see Descale section 2 Yo...

Страница 10: ...as purchased or to Dualit direct Ensure that the product is clean and packed carefully preferably in its original carton Enclose details of your name address and telephone number and when and where th...

Страница 11: ...ounty Oak Way Crawley West Sussex RH11 7ST 44 0 1293 652 500 info dualit com www dualit com GB A A feeding and weaning range designed to make everyday baby life that bit easier ORDER THE FULL RANGE AT...

Отзывы: