Dual Pumps SprayWash SW116PHR Скачать руководство пользователя страница 4

Model No.

SW116PHR

P

ump 

Information

Pump

Comet MC18 Diaphragm Pump

Speed

1450 RPM via Reduction Gearbox

Body

Polypropylene

Seals

Viton™

Pressure Regulator

Integrated PRV with external bypass

Engine 

Information

Engine

Honda GX120

Fuel

Petrol

Net Power

3.5 Hp @ 3600 Rpm in accordance with SAE J1349

Nominal Rpm

Engine 3600 - Pump

Starting Method

Recoil start

Fuel Tank

2 Litres

W

ater 

Connection

Max Feed Temp

40°C / 104°F

Min Feed Temp

5°C / 41°F

Min Feed Flow Rate

14.3 Lpm

Max Feed Pressure

0.01 MPa - 0.1 Bar - 1.45 psi

Max Suction Depth

1 Metre (3.3 Feet)

High Pressure 

P

erformance

Flow Rate

11 Lpm

Working Pressure

0.6 MPa

6 Bar

Pressure Outlet

Single Outlet

Nozzle Jet Size

30 x 4 (PENCIL, 15°, 25°, 40°)

Sound 

Levels

Uncertainty K

1 dB

SPL LWA dB*

62

GSPL LWA dB**

99

Oils

Pump Oil

ENI Blasia S 150 (ISO-L-CKD)

Gearbox Oil

ENI Grease MU EP

Engine Oil

Refer to engine user manual

W&D

Dimensions

900L x 600W x 700H (mm)

Weight

46 Kg

2. Model Information

The SW116PHR Washers consist of a diaphragm pump complete with pressure regulating 
unit coupled to a 4 stroke combustion engine via a reduction gearbox.

2

*SPL = Sound Power Level on equipment representative of this type
**GSPL = Guaranteed Sound Power Level for this equipment.
Notes

For the engine to reach it’s maximum power, and the unit to achieve full rated 
performance, the machine must be run in for at least 10 hours. The engine’s performance 
diminishes as altitude and ambient temperature increase. If the machine is to be used 
at altitude or with a high ambient temperature please refer to the engine user manual for 
guidance and any necessary precautions.

Содержание SprayWash SW116PHR

Страница 1: ...C M Y CM MY CY CMY K spraywash215x75 pdf 1 21 08 2018 09 03 20 Product id serial number information 793 1208 SW116PHR Washer User Manual...

Страница 2: ...ual highlights certain safety measures which should be taken in to consideration when using the Washer However each contractor and operator should make their own risk assessments whilst considering th...

Страница 3: ...se Warning The Washer is performance set at factory Do not adjust the engine governor or Washer valves unless qualified to do so Over loading of engine and components can lead to equipment failure per...

Страница 4: ...d Levels Uncertainty K 1 dB SPL LWA dB 62 GSPL LWA dB 99 Oils Pump Oil ENI Blasia S 150 ISO L CKD Gearbox Oil ENI Grease MU EP Engine Oil Refer to engine user manual W D Dimensions 900L x 600W x 700H...

Страница 5: ...l kinds and types inflammable liquids or liquefied gases edible liquids solvents and thinners of all kinds and types paints of all kinds and types liquids with temperatures above 40 C 104 F or below 5...

Страница 6: ...nozzles Figure 2 Standard accessories 4 Component Accessory Identification Figure 1 Washer Components 1 Trolley with 10 wheels 2 Engine 3 Pump 4 Mounting Flange Gearbox 5 Pump oil filler cap 6 Pressur...

Страница 7: ...sher to aid priming and water supply Ensure the filter is always below the water level Connect the bypass hose item 11 fig 2 to the bypass outlet on the pressure regulating valve item 9 fig 1 and put...

Страница 8: ...4 Choke off 7 Check engine oil Switch ON Safety Be careful Safety Be careful Do not use inside house Do not use inside house Read and understand the Owner Safety be careful Quick Reference Guide Quic...

Страница 9: ...no part of the motor pump and of the machine in which it is integrated is moving and no pipes contain liquid under pressure a Turn off the delivery pressure as described in point a in Pump Operation...

Страница 10: ...nd of the season or once a year Check and if necessary change the diaphragms Check the tightness of the motor pump screws Check the safety devices 8 Refer to the pump and engine manufacturer s manuals...

Страница 11: ...ce spark plug Over choking Open choke and crank engine over Engine falters or not running smoothly Choke is opened too soon Close choke until engine runs smoothly Engine shuts down during operation Ou...

Страница 12: ...lter dirty Clean the filter Not enough water supply or priming too deep Make sure the water supply flow rate or priming depth is in compliance with the indications in the Model Information page 2 The...

Страница 13: ...ts or materials of any parts upon return of the entire pump or other product or of the particular part to the Dual Pumps Ltd factory within the warranty period at the sole expense of the purchaser whi...

Страница 14: ...hether the claim is valid and if so will issue a credit for the item Should Dual Pumps Ltd find the claimed item to be out of warranty declarations the said charge will stand and be paid by the custom...

Страница 15: ...strial Estate Melton Mowbray Leicestershire LE13 1BS United Kingdom Person authorised to compile the technical file declaration Tom Herridge Product Manager Signed We hereby declare that the machine d...

Страница 16: ...nit 8 Hudson Road Saxby Road Ind Est Melton Mowbray Leicestershire LE13 1BS Telephone 44 0 1664 567226 Fax 44 0 1664 410127 E mail info dualpumps co uk www dualpumps co uk pumps DP SW116PHR V1 0 09 22...

Отзывы: