STEP
1
-Optional Direct Connect
Turn Off the Main Water Supply Line
1
Locate the cold water shut-off valve under the sink. Turn off the cold water supply to the existing kitchen sink.
NOTE: If uncertain about which line supplies the cold water, turn on the hot water to the faucet. Allow the water to heat up and carefully
feel the pipes under the sink. The pipe that remains cool to the touch is the cold water supply.
2
Turn on the cold water faucet on the kitchen sink to release pressure and allow water to completely drain from the line.
STEP
2
-Optional Direct Connect
Mount the System Head
1
Choose an easy-to-access area under the sink to mount the Filter System.
NOTE: To allow adequate space for filter changes, allow a minimum clearance of 4-6" below the QuickTwist
™
Filter. The Filter System
must be mounted in a vertical position.
NOTE: Mount the Filter System to a solid cabinet wall or wall. If a solid surface is not available, use hollow-wall anchor bolts or toggle
bolts (not included) to secure to the wall.
2
Remove the cap from the top of the System Head
A
. Using the Built-in Bracket on the back of the System Head or the template
provided on the back of this booklet, mark the holes for the Mounting Screws
C
on the wall surface.
3
Using a 1/8" drill bit, drill two pilot holes for the Mounting Screws. Insert Mounting Screws into the wall with a Phillips screwdriver,
leaving approximately 3/8" of each Mounting Screw exposed.
4
Hang the System Head on the eyes of the bracket and replace the System Head cap.
1
COLD WATER
VALVE
Optional Installment Method: Direct connect to Kitchen Faucet
NOTE: Undersink filters reduce water flow. If you wish to maintain unfiltered water flow for dishwashing, etc., we recommend
installing separate Faucet for Filtered Water (DuPont WFFT100 Series).
WFQT13000 & WFQT13500 Series
10
RIGID TUBING INSTALLATION
KITCHEN FAUCET
HOT WATER
VALVE
COLD WATER
VALVE
4-6”
FLEXIBLE TUBING INSTALLATION
KITCHEN FAUCET
HOT WATER
VALVE
COLD WATER
VALVE
2
Be sure that all electrical appliances and outlets are turned off at the
circuit breaker before working in cabinet area.
WARNING
Please wear safety glasses to protect
eyes when drilling.
CAUTION
V4.0
2
3
A
INLET
OUTLET