A-5
Alarm No
Description
Remedy
Drive power failure.
Check the safety circuit and the machine power
supply before initializing.
If the problem persists, please call an authorized
Service Technician.
007 022
007 023
007 024
007 025
007 026
WEB Waste, drive error
Motor could not move as expected.
Check for jammed plates and mechanical failures
before initializing.
If the problem persists, please call an authorized
Service Technician.
Drive power failure.
Check the safety circuit and the machine power
supply before initializing.
If the problem persists, please call an authorized
Service Technician.
007 027
WEB tension not reached.
The configured web tension in job file or in idle can't
be reached. Please check settings and web
threading.
007 028
Web waste roll is full.
Replace full waste roll with empty roll.
007 029
Web nonwoven roll is near empty.
Replace empty roll with new full roll.
007 030
Web PET roll is near empty.
Replace empty roll with new full roll.
007 031
Web break detected
When the processor has cooled down, remove
broken web and re-thread.
007 032
WEB NW, drive error -39022 Battery
low warning.
Please call an authorized Service Technician.
007 033
WEB PET, drive error -39022 Battery
low warning.
Please call an authorized Service Technician.
007 034
WEB Waste, drive error -39022
Battery low warning.
Please call an authorized Service Technician.
008 020
008 021
008 022
008 023
008 024
Format cylinder, drive error
Motor could not move as expected.
Check for jammed plates and mechanical failures
before initializing.
If the problem persists, please call an authorized
Service Technician.
Drive power failure.
Check the safety circuit and the machine power
supply before initializing.
If the problem persists, please call an authorized
Service Technician.
008 025
Format cylinder, drive error -39022
Battery low warning.
Please call an authorized Service Technician.
009 000
Catox. No flow sensed when required. If alarm can't be reset, please call an authorized
Service Technician.
009 001
Catox. TCO on heater element tripped. If alarm can't be reset, please call an authorized
Service Technician.
009 002
Catox. TCO on oxidizer tripped.
If alarm can't be reset, please call an authorized
Service Technician.
January, 2020
Operation Manual
|
Cyrel FAST 2000TD
Содержание Cyrel FAST 2000TD
Страница 37: ...Operation procedures 2 19 Blank January 2020 Operation Manual Cyrel FAST 2000TD...
Страница 38: ...3 0 Panel overview Panel overview Operation Manual Cyrel FAST 2000TD January 2020...
Страница 49: ...Control panel 3 11 Menu diagram January 2020 Operation Manual Cyrel FAST 2000TD...
Страница 86: ...Operation Manual Cyrel FAST 2000TD January 2020...
Страница 106: ...B 14 Appendix B Blank Operation Manual Cyrel FAST 2000TD January 2020...