User Manual
Ver. 1.04
22 di 35
X
BRICK
11.3 Protection
The use of a thermal magnetic circuit breaker is recommended for each X-BRICK.
12 DMX Signal Connection
The unit operates using the digital USITT DMX512 signal.
Connection between the light controller and the projector, or between projectors, must be carried out
using a two-pair shielded ø 0.5 mm cable, and a XLR 5 connector.
Ensure that the conductors do not touch each other. Do not connect the ground cable to the XLR
chassis. The housing of the plug must be isolated.
Connect the light controller to the DMX IN panel connector of the projector to create a link to the next
projector, simply connect the DMX OUT plug of the former to the DMX IN plug of the new fixture in
line.
Following this procedure, all the projectors will be cascade connected.
PS.
If the unit’s display is flashing when showing the DMX address, then one of the following errors has
occurred:
• DMX signal not present
• DMX reception problem
X BRIK
and
X BRIK Wireless
Содержание X BRICK