SLICE PRO Ethernet Controller User’s Manual
May 2019
11
13000-30610-MAN (Rev. 5)
3-4 hours from complete discharge to full capacity. It may be charged with or without
modules attached and it does not need to be ON in order to charge.
Charging practices can affect the useful operational life of the battery. In addition to good
charging habits, conditioning the battery may be useful
—three deep-discharge/recharge
cycles may help increase battery
performance. The battery’s useful capacity is greatly
shortened near the end of its service life and should be replaced when it has decreased to
50% of its initial capacity. The battery is not user-serviceable and should be returned to the
factory for battery replacement.
WARNING:
Due to battery chemistry, do not operate SLICE PRO DAS at
temperatures below 0°C (32°F) or in excess of 60°C (140°F).
SLICE PRO LAB systems do not contain internal batteries and must be connected to external
power at all times (15 VDC nominal; 9-15 V range at 40 W).
Power-up and Power-down Procedures
Firmly press and hold the power switch for 2 seconds to start or stop the system. Total time
from ON initiation to system ready is typically between 1-2 minutes. Multiple units in a chain
may be started in any order.
To restart a system, turn off the unit and wait ~30 seconds before reinitializing. If a system
is armed for data collection, it will remain on until it is disarmed or power reserves are
exhausted. An incomplete power-down/power-up cycle can result in errors, so be certain to
follow proper procedures.
CAUTION:
Do not turn off the Ethernet Controller if the system is armed.
You must disarm the system before initiating a system restart.